Beam
AEC
Exposure
Focus
kVp
100

If increased kVp is accompanied by an adequate reduction in ______, a reduction in scatter production will be realized.

mAs

100

Increased kVp has what effect on the production of scatter?

Increases it

100

Scatter that impacts the IR produces what kind of radiographic contrast?

Low contrast

100

Decreasing part thickness has what effect on scatter production?

Decrease

100

Increased beam restriction produces an image with:

higher contrast

150

What part of the beam forms the image?

The remnant beam

150

Increased beam- restriction has what effect on image brightness?

Has no effect

150

Which component of the collimator serves as about 1mm Al/Eq of filtration?

Mirror

150

Which component of a collimator serves to reduce off focus radiation?

Upper shutters

150

Which beam-restricting device is the most commonly used and offers an unlimited number of field sizes?

Collimator

200

During an exposure, the primary beam will either _______ or ______.

transmit without interaction, be attenuated

200

Of the factors affecting the amount of scatter produced, _______ and ______ are under the direct control of the radiographer.

kVp, field size

200

What is automatic collimation known as?

Positive Beam Limitation

200

Which beam restricting device is simply a piece of metal with a hole in it, attached to the port?

Aperture diaphragm

200

What device is used to help prevent scatter from striking the IR.

grid

200

When using AEC, the actual mAs the tube used for the exposure is ____.

Displayed after the exposure has terminated.

200

AEC chambers are filled with:

gas

200

When using an AEC technique, if the patient is positioned with more dense tissue, than the tissue of interest, over the activated chamber, the Exposure Index will indicate the IR was:

over exposed IR

200

When using an AEC technique, if the patient is positioned with less dense tissue, than the tissue of interest, over the activated chamber, the result will be:

under exposed IR

200

Early versions of AEC technology were referred to as

phototimers

300

When setting a manual technique, the radiographer must select which of the following?

mA

s

kVp

300

When an AEC is used for a lateral chest, which ionization chambers are utilized?

center cell

300

When setting an AEC technique, the radiographer must select which of the following?

mA

kVp

activated chambers

300

Automatic exposure devices provide a diagnostic quality radiograph when the

anatomy of interest is positioned directly above the appropriate ionization chambers.

300

A radiographer is performing an AP L-Spine radiograph using AEC. The manual technique for this exam would be 40 mAs at 80 kVp. The backup mAs the radiographer should set would be

60 mAs


40/2=20

40+20=60 = 150%