When registering a donor in DI, on the visit information screen, what question should be asked before moving to the next screen? (Visit information screen is where the form of identification and reason for donating is captured)
Group Code
What bag is used for directed donations when collecting whole blood?
Triple
What job aid is used when determining if QC is needed for apheresis products?
JA1636 - Apheresis instrument QC/Alarm messages
What does your pre donation materials include?
GC300B - Important information about HIV, AIDS risk, and testing practices, blood donor educational material
GC1657 - Medication deferral list
GC1657B - Additional health history reference
GC300A - After care pamphlet
When registering a donor in DI, on the product type selection screen, what should you review before moving to the next screen? (Product type selection screen is where the donation type is captured)
Special Process Code
When performing a venipuncture, after the initial phlebotomy, you should tape the needle down first than remove the stats.
False: You should remove the stats first and ensure you have a good flow before taping the needle down.
What is the first step when loading the Trima collection tubing set?
Select the appropriate tubing set on the screen.
Team QNS should be --- or below.
2.5%
If a donor has special process code DNFF, the donor cannot donate what product or donation type?
Anything with a red cell, including WB. Can ONLY donate plts or plasma.
For the hemaflow, what job aid is used to determine collection volumes if the donor does not qualify for VBV?
Job Aid JA1659, Automated and Manual WB Collection Targets
When collecting multiple components (CR) the DINs should be attached to what components?
Pls/Rbc
What is the service vision statement?
Create experiences that inspire others to save lives each and every day!
If your donor completed CFL express and does not have the QR code either printed or electronically, how should you proceed?
Inform the donor they will have to answer the questions again using DI.
A Q51 completion code is used when blood reaches the sample pouch, but the donation is not successful.
False - 3rd notch or more
When collecting 2RBC inline, what clamps should be closed prior to starting the procedure?
Red and white
Sugar Lands monthly automation goal is what percent?
60% or above
When checking the hemoglobin and the hemoglobin is low, it is acceptable to switch hands or fingers for the second reading.
False: The same hand and finger should be used for both readings.
What is the eligibility period for a 18-year-old female donating whole blood?
112 days (16 Weeks)
When sealing apheresis products or tubing, how many seals are required for all seals per SOP.
3
Apply the first seal below the blue sleeve towards the component.
Apply the second seal on the blue sleeve.
Apply the last seal above the blue sleeve. (Closest seal to the filter.)
Sugar Lands coll. vs. off. monthly goal is what percent?
84% or above