length of grounding conductor or ground wire should be no more than
6 meters (20 feet)
digital 256 QAM levels
-8 to 10 dBmV
4 parts of coax
Center conductor, dielectric, braid & shield, outer sheath
cable clips needed when running cable horizontally
every 18-24 inches
how to drill on wood siding
inside out
grounding conductor shall not exceed
#6 AWG size
downstream SNR minimum level
35 dB
these must not be used on coaxial drop cables
metal staples
cable clips needed when running cable vertically
every 30-36 inches
how to drill through anything but wood
outside in
this must be done before hooking up customer equipment
bond to house ground system
upstream SNR minimum level
31 dB
Cables for underground installations must
have a polyethylene (PE) jacket; have a flowing, self-healing flooding compound or braid wires
Max length of Cat 5 cable
328 feet
drill holes should
be drilled with outside hole slightly below inside hole (5 degree angle)
bonding option 2
to ground conductor
upstream receive power level
-2 to 2 dBmV
drop cable must be replaced if
copper braid,
solid dielectric material,
inner foil bonded to dielectric,
series 59 cable interfering with RF
wall plates must have
7/16" hex recess to hold the F-81 and prevent it from turning
Holes should be driven no closer than
1 1/2 inches from each other
General guidelines for bonding/grounding at the home
NEC Article 800
MER 256 QAM minimum threshold
35 dB
approved cables
minimum size
of Series 6 with a minimum foil-braid-foil, tri-shield configuration that includes a bonded inner foil tape, outer foil tape bonded to the jacket, and at least 77% braid coverage
Size of hole for single cable
1/2 inch
seal holes with
RTV sealent or calking