Egress &
Accessibility
Healthcare
Public Restrooms
Doors
Finishes
100

The maximum egress distance in a B occupancy building with sprinklers.

What is 100'-0"?

100

Handrails are required in this area of the hospital.

What are patient corridors?

100

The minimum clear floor space in front of a water closet.

What is 60" x 56"?

100

This is the minimum ADA clear width of a door.

What is 32"?

100

The recommended slip resistant rating for dry flooring.

What is .42?

200

Changes in level up to 1/2" may be beveled at a slope no steeper than this.

What is 1:2?

200

The organization that develops guidelines used for designing and building hospitals, outpatient facilities and residential health care and support facilities.

What is Facilities Guideline Institute (or FGI)?

200

Standard transfer type shower compartments must be this dimension.

What is 36" x 36"?

200

The space between two doors in a series beyond the door swing.

What is 48"?

200

This type of flooring and wall base is required in Sterile areas.

What is integral flooring and 6" base.
300

The minimum width of a commercial hallway or passageway.

What is 36"?

300

In restricted access treatment areas, this type of base is required.

What is 6" high integral base?
300

The side wall grab bar is this long (minimum) and no more than this from the inside corner.

What is 42" long and 12" max from the rear wall?

300

The minimum clear dimension between the latch side of a door (push side/swinging inward) and an adjacent wall running perpendicular to the door wall.

What is 12"?

300

Ceiling tiles in Procedure rooms must meet these requirements.

What is scrubbable and gasketed or weigh 1 lb/sq. ft.?

400

The minimum clear floor space designated for a wheelchair, depth and width.

What is 30" x 48"?

400

The minimum width of an exit access corridor within a hospital patient area.

What is 8'-0"?

400

The minimum dimension between the center of an accessible water closet and a side wall.

What is 18"?

400

The minimum clear dimension between the latch side of a door (pull side/swinging outward) and an adjacent wall running perpendicular to the door wall.

What is 18"?

400

Cubicle curtains must meet this safety code.

What is NFPA 701?

500

The maximum dead end corridor distance in a sprinklered Type B building.

What is 50'-0"?

500

This type of decorative element feature is not permitted in a hospital.

What are open water features?

500

Mirrors located above restroom lavatories or countertops shall be installed at the bottom edge of the reflecting surface at this maximum distance above the finish floor.

What is 40"?

500

Doors may encroach no more than this fraction into a corridor that is part of a means of egress path.

What is 1/2?

500

Handrails shall be mounted in this dimension range.

What is 34"-38"?