Minimally Invasive
Minimally Invasive
Minimally Invasive
Minimally Invasive
Minimally Invasive
100

Pelviscopy, bronchoscopy, and colonoscopy are all types of:

Diagnostic Endoscopy

100

After the Veress needle is inserted and the plunger is pulled back the CST and the surgeon observe the barrel of the syringe, why:

Saline is placed in the plunger via a syringe - IF the saline flows down this confirms the proper placement of the veress needle in the abdominal l cavity if the saline stays in the plunger of the veress needle it needs to be repositioned

100

Type of endoscope appropriate for examination of the renal pelvis via a natural body orifice

Flexible Ureteroscope

100

Describes the right and left (side-to-side) movements of a robotic manipulator that has 3D capability.

yaw

100

The purpose of the patient side cart during a robotic-assisted procedure is to:

Appropriately position the patient next to the robotic system.

200

The unsterile component of the endoscopy is:

TV Monitor

200

HALS stands for:

Hand-assisted laparoscopic surgery.

200

The term defines the number of ways that a robotic manipulator can move

degrees of freedom

200

The complex robotic operating system created and marketed by Intuitive Surgical® is:

da Vinci.

200

The size of a hybrid OR suite should be:

a minimum of 1000 square feet

300

The rigid endoscope is described as:

A metal tube with an eyepiece.

300

The typical rate of gas flow for insufflation is:

three to four liters per minute.

300

The generation of robots requires consistent oversight not having any artificial intelligence (AI)

First Generation
300

A term used for the technology of performing a surgical procedure in real-time but from a distant location?

Telesurgery

300

A patient who is in the process of obtaining pre-operative positional data is undergoing:

registration.

400

White balance is completed by the CST by:

aiming the endoscope a few inches away from a 4x4 Ray-tec, then engage the white balance button.

400

Intraabdominal pneumoperitoneal pressure for an average adult should be kept between:

twelve to fifteen mmHg.

400
Resolution is the term that defines:

The extent to which a machine, microscope, human, or robot can differentiate between two objects?

400

A robotic manipulator is not sterilized but covered with disposable drapes for surgical procedures. (T/F)

True

400

A small object placed on or in the body to indicate a specific area for treatment?

Fiducial Marker

500

FRED stands for:

Fog reduction elimination device.

500

The correct order for the surgical approach to an abdominal laparoscopic procedure is:

incision into the skin

Veress needle placed and checked with saline

Insufflation

Trocar insertion.

500

During routine robotic surgery procedures, the surgeon is located:

At the robotic console separate from the OR table.

500

Used for graphing mathematical functions in which the axes are always perpendicular to each other?

Cartesian coordinate

500

The procedure that delivers a clotting agent to a specific area in the body using interventional radiology is called:

Embolization.