What is the maximum trap arm length for 1-1/2" drain?
3.5'
What is the max Gpm for a 2" pipe on grease interceptor?
20GPM
Building traps shall not be installed except where required by the ____________
Authority Having Jurisdiction
True or false?
Sand interceptors can be built out of bricks
True
Does a car repair garage require a interceptor?
Yes
What is the maximum trap arm length for 3" drain pipe?
6'
What is the max Gpm for a 4" pipe on grease interceptor?
125 GPM
What does each building trap need for maintenence?
Cleanout
What is the minimum inlet size for a sand interceptor?
3"
What is the minimum vent size for a flammable waste interceptor
2"
What is the maximum trap arm length for a 2" drain pipe
5'
What is the max Gpm for a 3" pipe on grease interceptor?
60gpm
What also is required on the inlet side of the trap to ensure proper flow?
Vent
What size is the outlet of a 3" sand interceptor?
3"
Oil and flammable interceptors shall be installed with what kind of cleanout?
gas tight cleanout
What is the maximum trap arm length for a 4" drain pipe?
10'
What is the max Gpm for a 5" pipe on grease interceptor?
230gpm
What is the minimum required vent size for a building trap?
Half the diameter of the building trap size
Are the inlet and outlet of a interceptor inline with one another or offset?
offset
Can waste oil from an interceptor be pumped out or gravity fed?
Both
What is the formula to find the cross sectional value of a pipe?
Pipe size X Pipe size X .7854
What is the max Gpm for a 6" pipe on grease interceptor?
375gpm
Where does the the building trap terminate?
Above grade outside of building
Can the inlet pipe be lower than the outlet pipe on a interceptor?
NO
What else is required on the cleanout that severs the flammable waste interceptor?
Must be readily accessible.