Category One
Category Two
Category Three
Category Four
Category Five
100

Electric heating equipment is typically

less expensive to purchase and more expensive to operate than fossil fuel heating equipment.

100

Electric baseboard heaters are typically controlled by

heater-mounted line-voltage thermostats

100

Three common controls used in central electric heat applications are

thermostats, contactors and sequencers

100

The heat anticipator is a(n)

adjustable device that is wired in series with the thermostat’s heating contacts.

100

Dirty air filters on an electric forced-air furnace can cause

reduced airflow and increased internal appliance temperature

200

Portable or small space heaters with glowing coils transfer heat by

radiation

200

From an installation standpoint, electric boilers have the benefit of not requiring

flue or vent piping

200

The fusible link is best described as a(n)

one-time, safety device

200

The sequencer is responsible for

staggering the starting and stopping of multiple stages of electric heat.

200

On furnaces that are equipped with belt-driven blower assemblies, which of the following can result if the belt is too loose?

Reduced airflow and increased internal appliance temperature

300

If the distance between a heat source and the heat target is doubled, the amount of sensed heat at the target location will be

one-quarter of the amount of heat sensed at the initial location.

300

What is the approximate efficiency of an electric furnace with respect to its ability to convert electrical energy to heat energy?

100%

300

Which of the following statements is true regarding the limit switch and the fusible link?

The fusible link melts at a temperature that is higher than the temperature at which the limit switch opens.

300

The wiring diagram that shows the location of each system component is the

pictorial diagram.

300

If the proper voltage is supplied to an electric heating element and it does not get hot,

the heating element is defective.

400

Electric radiant heating elements

are often controlled by individual thermostats.

400

The electric resistance strip heaters in an electric furnace are insulated from the rest of the appliance using which materials?

Mica or ceramic

400

The low-voltage thermostat is often used to control an electric heating system because it is compact, quick to respond to load changes, and it

is safe

400

Referring to Figure 30.22, the indoor fan motor will operate at low speed

whenever the high-voltage disconnect switch is closed and sequencer contacts 3-4 are closed.

400

If the thermostat is calling for heat, but the appliance is providing insufficient heat, which of the following is the most likely cause for system malfunction?

The supply voltage to the appliance is too low.

500

Baseboard heaters transfer heat by

 convection

500

What is the purpose of an interlock circuit on an electric forced-air furnace?

It prevents the heaters from coming on if the blower is not energized.

500

An isolating thermostat subbase is easily identified because it has which of the following terminals?

RH and RC

500

Referring to Figure 30.23, each electric strip heater is protected by how many safety devices?

4

500

The material often used to manufacture electric strip heater element wire is

nickel chromium (nichrome).