Sterilization
Reassembly
Patient Care Items
Chemicals and Cleaning
Disinfection, Disassembling and Decontamination
100

Which method of sterilization is the most popular and cost efficent?

Steam

100

How should air hoses of powered instruments or fiber-optic light cords be placed in rigid container trays for sterilization?

coiled loosely in perforated or mesh basket

100

A pulse oximeter would be classified as a _____ patient care item

noncritical

100

What is the term for inanimate objects that harbor microorganisms that contribute to environmental contamination?

Fomites

100

Which part of the instrument reprocessing cycle is performed intraoperatively?

wiping with sterile water, intermittent cleaning

200

Which type of packaging system has filters and removable locking devices? 

Rigid Containers

200

When nested basin sets are being sterilized, how should they be placed in the steam sterilizer?

fold side down with a towel used to separate them

200

These items require either intermediate-level or low-level disinfection

non critical

200

Which of the following chemicals is a high level disinfectant when items are immersed for 20-30 minutes and a sterilant if items remain immersed for 10 hours

Cidex (Glutaraldehyde)

200

Which part of the instrument reprocessing cycle is performed postoperatively?

Spraying with enzyme solution, disassembling

300

Which concept has replaced the previous system of assessing storage conditions and package integrity based on an arbitrary expiration designation?

event related sterility

300

Why are large steam sterilizers loaded with space between wrapped items or trays?

It allows adequate circulation and penetration of steam to all surfaces.

300

Implantable items (wires, screws, joint replacements, mesh, sutures) would be classified as a _____ patient care item

critical

300

What type of solution would be appropriate for animate objects?

Antiseptic

300

What is the type of process the ultrasonic cleaner uses to dislodge minute particles of soil and organic debris?

Cavitation

400

What is the weight that AAMI has recommended instrument sets should NOT exceed?

25 pounds

400

What is a potential risk of placing surgical instruments of dissimilar metallic type together in a washer sterilizer cycle

electrolytic conduction reaction

400

High-level disinfection should be used for items in this category

Semi- Critical

400

Which type of chemical solution is made of catalysts that aid in breaking down proteinaceous debris such as blood and fat?

enzymatic

400

What is the term used to describe the process of removing all soiled linen, waste, and instruments from the room and cleaning of furniture, floors, or other contaminated surfaces in preparation for opening new supplies for a subsequent case?

turnover

500

The biological indicator (BI) for the steam sterilization method is:

Geobacillus stearothermophilus

500

Why are items disinfected or sterilized in activated glutaraldehyde dried prior to submersion?

Moisture will eventually dilute the concentration to ineffective levels.

500

True or false: It is appropriate to use immediate use steam sterilization for implantable devices

FALSE!!!

500

What is another name for the intermediate-level disinfectant compound phenol?

carbolic acid

500

During manual cleaning of surgical instruments, what type of solution should be used?

lukewarm water, detergent, and enzymatic cleaner with neutral pH