When install in a raceway conductor size ____ and smaller can be solid?

Code Reference (Indirect):

10 AWG

310

100

Article 240 Part VI covers?

 Cartridge Fuses and Fuseholders

100

The NEC requires the grounded conductor to be identified using this color.

Code Reference: 

White or Gray continuous outer finish

200.6

100

What article covers switches

Article 404

100

Floor outlets that are 24" or closer to the wall are counted as a required outlet when doing calculations per wall space requirements? True or False?

Code Reference: 

False

210.52(A) (

200

What article covers over current protections.

Article 240

200

How do you identify a grounded conductor?

Code Reference:

White or Gray outer finish.

200.6(A)/(B)

200

A multiwire branch circuit must have this in the panelboard to ensure simultaneous disconnection of all ungrounded conductors.

Common trip breaker or handle tie

(2 or 3 pole breaker). 

200

What article covers grounding and Bonding

Article 250.

200

A wall measuring 3' will require an outlet? True or False?

Code Reference?

False

210.52(A)(2)(1)

300

Which dwelling unit areas is not included in the general provisions of NEC 210.52(A) where 125-volt, 15- and 20-ampere receptacles are required to be located?

A. Sunroom 

B. Living Room

C. Closet

D. Rec Room

Closet

300

How do you identify a branch circuit supplied from Direct-Current System with positive polarity?

Code reference:

Continuous red outer finish. 

210.5(C)(2)(1)

300

Max load permitted on a 15A Circuit for cord and plug connected equipment not fastened in place?

Code Reference:

12A

210.23(B)(1)

300

Pertaining to kitchens countertops, no point on the wall line can be more than ____inches from an outlet. In other word you need to have an outlet ever ___ feet. 

Code Reference:

24" and 4'

210.52(C)(1)

300

Voltage between conductors for Lighting in guest rooms or guest suites of hotels, motels, and similar occupancies is permitted to be 277v? True/False

Code Reference:

False (120 V)

210.6(A)(1)

400

NEC 240.4 requires overcurrent protection to be sized according to this characteristic of a conductor.

Ampacity
400

Flush-type general-use snap switches mounted in boxes that are flush with the finished surface or project from it shall be installed so that the mounting yoke or strap of the device is seated against the _____?

Code Reference:

 Box

404.10(B)

400
How much do I weigh?

270Lbs

400

Receptacles installed in damp or wet locations have to be listed ________

Code Reference:

WR- Weather Resistant 406.9(A) 406.9(B)

400

A hallway in a dwelling unit that is 9'11", will require at least 1 receptacle? True or False?

Code Reference:

False

210.52(H)

500

At least one lighting outlet controlled by a listed _______ device shall be installed in every habitable room, kitchen, and bathroom. The __________ device shall be located near an entrance to the room on a wall. But for other than kitchen and bathrooms, one or more receptacles controlled by a listed ________ device shall be permitted in lieu of lighting outlets.

Code Reference: 

wall-mounted control (X3)

210.70(A)(1) Exception No. 1

500

Receptacles shall be listed and marked with the _____ or identification and voltage and ampere ratings.

Manufacturer’s name

406.3(A)

500

A 3 phase 4 wire 277/480 v system is installed in a gas pumping station. How do you identify the ungrounded conductors?

Code Reference:

Per 210.5(C)(1)(a)

There is no code requirement for specific colors.

B.O.Y and BK.R.BL are industry standards no code requirement.

500

For a single-family dwelling unit, a single receptacle outlet is required to be installed in what locations (3 required)?

Code References: (3 total)

210.52 (E) (F) (G)

500

Circuits more than _____, nominal, to ground and not more than ______  , nominal, between conductors shall be permitted to supply the auxiliary equipment of electric-discharge lamps mounted in permanently installed luminaires where the luminaires are mounted not less than a height of 22 feet on poles or similar structures for the illumination of outdoor areas such as highways, roads, bridges, athletic fields, or parking lots.

Code Reference: 

277 V / 1,000 V 

210.6(D)