definitions
conductors
overcurrent protection
devices/j boxes
misc
100

connected to establish electrical continuity and conductivity 

bonded 

100

the w in thwn stands for what 

water resistant 

100

which of the following is not a standard size fuse?

40, 50, 55, 60 

55

100

how many small appliance circuits are required to be installed in a kitchen of  a single family dwelling 

2

100

DAILY DOUBLE 

what is the minimum distance an outlet is allowed to be installed from a pools inside wall. 

6

200

electrically connected to, or is , a source of voltage 

energized 

200

table most used when  associated with conductor ampacities 

table 310.16 

200

what does the acronym mccb stand for 

molded case circuit breaker 

200

what identify mark is on a hospital grade outlet 

green dot 

200

what is the percentage of full load current  that a time delay fuse is multiplied by when using a single phase motor 

175

300

the current delivered at a point on the system during a short circuit condition 

fault current 

300

according to table 310.15 c 1 what is the multiplying factor for derating a pipe with 7-9 current carrying conductors 

70 percent 

300

DAILY DOUBLE 

where the overcurrent device is rated over  ____ amps, the ampacity of the conductors it protects shall be equal to or greater than the rating of the overcurrent device 

800

300

all switches and circuit breakers shall be located so that they can be operated from a _______ ______ place. 

readily available 

300

what are the two table in article 250 that refer to egc sizing 

250.66 and 250.122 

400

constructed so that moisture will not enter the enclosure under specified test conditions 

watertight 

400

what is the smallest size wire that is allowed by code to be used as a parallel conductor(s) 

1/0 

400

a conductor, other than a service conductor that has overcurrent protection ahead of its point of supply that exceeds the value permitted for similar conductors that are protected 

tap conductor 

400

what is the minimum spacing between the pipes on the top and the side of a  j box that is required for the following situation

4 (2) emt pipes entering the top and leaving out the side 

12 inches 

400

what is the burial depth of a 2" pvc that is under a driveway

24 inches

500

an electrical source, other than a service, having no direct connection(s) to circuit conductors of any other electrical source other than those established by grounding and bonding connections 

separately derived system 

500

according to table 310.12 what size copper wire would be used for a single phase dwelling service of 200 amps 

2/0 

500

overcurrent protection shall be provided in each underground circuit conductor and shall be located at the point where the conductors receive there ______.

supply 

500

how many number 10 wires can be fit into a 4" sq by 21/8" deep combo box 

12

500

name the 4 egc that must be used on a commercial bldg if they re available 

cwp

building steel 

upher

delta 

M
e
n