100

Who publishes the Electrical STANDATA?

The Safety Codes Council

100

What is the term for a person familiar with the construction and operation of certain apparatus, and who is familiar with the hazards involved?

A qualified person

100

What is the term for equipment constructed without live parts exposed to a person on the operating side of the equipment called (according to the CE Code)

Dead front - Section 0

100

What is the white insulated conductor supplied by a 2-wire circuit and terminated on a 5-20R receptacle called?

Identified conductor

100

The neutral conductor shall have sufficient ampacity to carry the balanced load current. True or false?

False. It needs to carry the UNbalanced load. 4-018 1).

200

Which sections of the CE Code are the general sections?

0-16 and 26

200

When must the electrical permit for carrying out work on electrical installations be obtained?

Before commencing work. 2-004

200

What must be done with plans and specifications for buildings in which public safety is involved?

Submitted to the inspection department for approval. 2-014

200

What is the smallest aluminum conductor that can be used for branch circuit wiring?

No. 12 AWG. 4-002

200

When equipment is separated from other conducting surfaces by a dielectric material having a degree of resistance to the passage of current, it is said to be what?

Insulated

300

How many technical councils make up the Safety Codes Council?

10

300

What type of flux is required to be used for soldering copper?

Non-corrosive. 2-118

300

What is the CSA designation for an enclosure suitable for use indoors where the air may contain settling non-hazardous fibres?

Type 5. Table 65

300

What is the ampacity correction factor for 12 copper conductors in a raceway or cable?

70%. Table 5C

300

Which table is used to determine whether NMD90 is suitable for a particular condition of use?

Table 19

400

Aside from the CE Code, name ONE other code that also affects electrical installations?

National Fire Code

National Building Code

400

With certain exceptions, what is the maximum voltage-to-ground of branch circuits in dwelling units?

150V. 2-110

400

What must be done if defective electrical equipment can not be put in good working order?

It must be permanently disconnected. 2-300(4)

400

Unless appropriately marked, flexible cord shall not be used for the suspension of any device weighing more than _____?

2.3kg. 12-402(3)

400

If conductors are installed in a room exceeding 30C ambient temperature, which table is used to apply ampacity correction factors?

Table 5A

500

What is the American equivalent of the CE Code?

NEC - National Electrical Code

500

Name 2 of the 4 subtopics into which the Technical Rules in Section 2 are divided.

General

Protection of Persons and Property

Maintenance and Operation

Enclosures


500

Name 3 pieces of information that the nameplate of a washing machine must include.

Maker's name, trademark, or other recognized symbol of identification; Catalogue number or type; Voltage; Rated load amperes; watts, volt amperes or horsepower; whether for ac, dc, or both; number of phases; frequency in hertz; rated load speed in rpm; designation of terminals; whether for continuous or intermittent duty; short-circuit current rating or withstand rating; evidence of approval, etc. 2-100


500

What is the conductor colour coding for a single-phase dc, 2-wire circuit?

1 black, 1 red. OR 1 black, 1 white. 4-032

500

What is the conductor colour coding for a 3-phase ac circuit?

1 red, 1 black, 1 blue (and 1 white if a neutral is required). 4-032.