This standard sets the minimum energy efficiency requirements for HVAC and lighting controls.
What is ASHRAE 90.1?
A minimum clearance in front of electrical panels of 36 inches is required.
What is NEC Article 110?
This international code sets the rules for energy conservation in buildings.
What is IECC?
Thermostats should be mounted at this height above the floor for ADA compliance.
What is 48 inches?
BAS must always defer to this system during an emergency.
What is the fire alarm system?
This standard defines minimum outdoor air ventilation rates for buildings.
What is ASHRAE 62.1?
This article requires all BAS panels and cables to be properly grounded and bonded.
What is NEC Article 250?
This California code requires demand response and advanced FDD in large BAS.
What is Title 24?
Motion sensors are typically mounted around this height above the floor.
What is 80 inches (about 7 ft)?
Opening smoke exhaust fans and pressurizing stairwells is part of this BAS sequence.
What is smoke control?
This standard ensures devices from different vendors can communicate.
What is ASHRAE 135 (BACnet)?
BAS wiring is classified as this type of circuit class 2 or class 3 circuits.
What is NEC Article 725?
This code ensures BAS integrates with fire/smoke damper control.
What is IBC (International Building Code)?
This device trips at ~38°F to protect coils from freezing.
What is a freezestat?
Separating BAS from the corporate IT network is called this.
What is segmentation?
This BAS feature learns how early to start AHUs so rooms reach setpoint by occupancy time.
What is optimum start?
A local disconnect is required to be “within sight” of a VFD-driven motor.
What is NEC Article 430?
Resetting chilled water or static pressure based on load is a requirement under this ASHRAE standard.
What is ASHRAE 90.1?
This device trips around 120–140°F to prevent fire/smoke spread.
What is a firestat (high-limit stat)?
BACnet/SC uses this type of encryption for secure communication.
What is TLS (Transport Layer Security)?
Using CO₂ sensors to vary outside air in conference rooms or schools is an example of this strategy.
What is demand-controlled ventilation (DCV)?
In ceiling plenums, CMP (plenum-rated) Cat cable is required.
What is NEC Article 800?
A building running systems 24/7, wasting energy and failing audits, likely ignored this code.
What is IECC (or ASHRAE 90.1)?
Outside air dampers that close on power loss are an example of this device type.
What is fail-safe (spring return)?
A vendor uses an approved client to connect remotely to BAS.
What is a VPN?