What's That Occupancy?
Carrying the Load
You're On Fire!
Finishing Touches
Free For All
100

THIS OCCUPANCY CLASSIFICATION RELATES TO BUILDINGS OR SPACES FOR THE TRANSACTION OF BUISNESS

WHAT IS BUSINESS – B GROUP?

100

CALCULATIONS USED TO DETERMINE HOW MANY PEOPLE CAN SAFELY ACCESS AND USE  SPACES AT ONE TIME

WHAT IS OCCUPANT LOAD?

100

THE BEST-KNOWN TEST FOR EVALUATING BUILDING MATERIALS FOR FIRE SAFETY, COMMONLY KNOWN AS THE TUNNEL TEST

WHAT IS ASTM E 84?

100

THIS WALL COVERING IS DESIGNED TO BE USED IN HIGH TRAFFIC AREAS, SUCH AS CORRIDORS, AND TYPICALLY HAS AN OUNCE WEIGHT BETWEEN 20-28 OUNCES

WHAT IS TYPE II WALL COVERING?

100

PREVENTS MOISTURE AND EVERYDAY SPILLS FROM PASSING THROUGH THE FABRIC, WHILE ALSO MAINTAINING SANITARY STANDARDS

WHAT IS MOISTURE BARRIER BACKING?

200

THIS OCCUPANCY CLASSIFICATION IS DETERMINED WHEN A BUILDING IS OPEN TO THE PUBLIC AND USED FOR DISPLAY, SALE OR RENTAL OF MERCHANDISE

WHAT IS MERCANTILE – M?

200

WHEN MULTIPLE SPACES WILL BE EXITING INTO A COMMON AREA OR COMMON PATH OF TRAVEL

WHAT ARE CONVERGING LOADS?

200

THIS TEST METHOD APPLIES TO CURTAINS, WINDOW SHADES, DRAPERIES AND TEXTILE WALL HANGINGS

WHAT IS NFPA 701?

200

THE MINIMUM DOUBLE RUB RATING REQUIRED FOR UPHOLSTERY FABRICS

WHAT IS 30,000 DOUBLE RUBS?

200

THE MINIMUM RATING OR CLASSIFICTATION LIGHT FIXTURES MUST COMPLY WITH (BOTH DRY OR WET/DAMP RATED)

WHAT IS UL LISTED?

300

THESE OCCUPANCY CLASSIFICATIONS ARE DETERMINED WHEN A BUILDING INCLUDES CARE OR SUPERVISION OF OCCUPANTS, INCLUDING MEDICAL CARE

WHAT IS INSTITUTIONAL – GROUP I?

300

THE PREDETERMINED AMOUNT OF AREA OR SQUARE FEET REQUIRED FOR EACH OCCUPANT BASED ON THE SPECIFIC USE OF THE SPACE

WHAT IS LOAD FACTOR?

300

COMPRISED OF SIX LABORATORY TESTING PROCEDURES FOR EVALUATING THE PERFORMANCE OF UPHOLSTERED FURNITURE COMPONENTS WHEN EXPOSED TO SMOLDERING CIGARETTES

WHAT IS NFPA 260 OR UFAC CLASS I?

300

FABRICS THAT ARE NOT SUPPLIED BY THE FURNITURE MANUFACTURER

WHAT IS COM FABRIC?

300

THIS TEST METHOD MEASURES THE FRICTION BETWEEN THE FLOORING SURFACE AND THE OBJECT MAKING CONTACT WITH THE FLOOR

WHAT IS DYNAMIC COEFFICIENT OF FRICTION (DCOF)?

400

THESE OCCUPANCY CLASSIFICATIONS MUST HAVE MORE THAN 50 OCCUPANTS

WHAT IS ASSEMBLY – A GROUPS?

400

REFERS TO THE BUILDING AS A WHOLE AND INCLUDES ALL MISCELLANEOUS SPACES WITHIN THE EXTERIOR WALLS

WHAT IS GROSS AREA?

400

INDICATES THE SPEED AT WHICH A FIRE MAY SPREAD ACROSS THE SURFACE OF A MATERIAL

WHAT IS FLAME SPREAD INDEX (FSI)?

400

UHOLSTERY FOAM MUST MEET THIS CODE REQUIREMENT

WHAT IS CAL 117?

400

THE MINIMUM FOAM DENSITY FOR UPHOLSTERED FURNITURE

WHAT IS 1.8 LB FOAM?

500

THIS CLASSIFICATION HAS FOUR SUBCLASSIFICATIONS THAT PROVIDE SLEEPING ACCOMMODATIONS

WHAT IS RESIDENTIAL – R GROUPS?

500

REFERS TO ACTUAL OCCUPIED SPACES AND DOES NOT INCLUDE ANCILLARY SPACES SUCH AS CORRIDORS, RESTROOMS, UTILITY CLOSETS OR UNOCCUPIED AREAS

WHAT IS NET AREA?

500

OCCURS WHEN THERE IS NO RATED SEPARATION ASSEMBLY BETWEEN TWO OCCUPANCY SPACES, WHERE BOTH MUST MEET THE REQUIREMENTS OF THE MOST RESTRICTIVE OCCUPANCY TYPE

WHAT IS A NON-SEPARATED MIXED OCCUPANCY?

500

ENABLES UNTREATED FABRICS TO MEET COMMERCIAL STANDARDS BY DECREASING THE FABRIC’S ABILITY TO IGNITE AND SLOWING THE FLAME SPREAD

WHAT IS FLAME RETARDANT BACKING?

500

FABRICS THAT RESIST CATCHING ON FIRE, CHAR INSTEAD OF BURN AND TERMINIATE THE FLAME AFTER THE IGNITION SOURCE IS REMOVED

WHAT IS FLAME RESISTANT?