Solar Basics
Solaredge Systems
Sonnen Core/AC Hub
Diagnostics
Electrical
100

Solar panels create this type of power

What is Direct Current (DC Power)

100

A Solaredge battery is coupled on this side of the inverter

DC side or DC Coupled

100

This many stacked core batteries and solar inverter inputs are inside of an AC Hub

What 3 core batteries and 2 solar inverters (One 63amp, One 40amp)?

100

This bad component will cause communication issues throughout the inverter and anything connected to it

What is a bad Communication Board?

100

These are acceptable names for residential electrical power (Name One)

What is single-phase, split-phase, 120/240 volt?

200

Solar Production is created by the displacement of this particle by photons within solar panel cells.

What is Electrons?

200
This device triggers the transfer switch to close when the grid is re-established after an outage has occured

What is Hub Inverter?

200

This location is where CT's are located with an AC Hub system

What is the AC Hub except when any loads are present further upstream of the AC Hub?

200

This battery does not show up on findmysoonenbatterie.com

What happens when battery isn't connected to server?

IP address issue, Yellow Halo, Router rejection of battery.

200

The most common voltage for 3 phase power (like in a barn or a shop) commonly indicated by L1 black, L2 Red, L3 Blue

what is 3 phase 120/208v power?

300

Silicon Solar Cells are doped with these two other elements.

Boron, Phosphorous

300

This many amps are available in backup in a 7.6/7.6 KW Hub Inverter.

What is 32Amps?

300

The Sonnen Core can supply this many continuous amps (backup mode, on-grid mode)

Backup mode 20amps

On-grid mode 20amps

300
The result of Rapid Shutdown open circuit or internal circuitry failures in the inverter

(explain)

What is a RSD error?

300

This device uses the relationship of amperage and voltage in ohms law to adjust outputs to maximize total watts produced.

what is an MPPT (max power point tracking), or DC-DC converter, or Optimizer TM?

400

There are this many bypass diodes within a solar panel

2

400

Solaredge batteries initiate communication over this method A(Energy Net) B(RS485-1 Hardline) C(DC Power Lines)

C. What is DC Power Lines?

400

This device uses magnetic switching to allow a control device with low voltage to open or close a switch of high voltage

What is a Relay?

400

This many volts indicates a blown-open optimizer

What is a full panels voltage? (32 volts in good lighting conditions)

400

These are all applicable building codes and years as amended in Utah law to solar

what is 2020 NEC national electrical code, 2015 IRC international residential code, 2018 IBC international building code, 2018 IFC international fire code

500

These factors are involved in the Standard Testing Conditions (STC) sizing of a solar panels

1.Light Irradiance of 1000 Watts/Meter Squared (air mass density 1.5am) Spectrum.

2. Internal Cell Temperature of 25C (77F)


500

This Model Number of 7.6KW Hub Inverter compatible with BOTH SolarEdge and LG Prime Batteries

What is SE-7600H USSNBBL14, SE-7600H USMNBBL14 (7.6/10)

500

The inverter in the Sonnen Core battery is capable of inverting this many Kilowatts?


What is 6KW?

500

This grounded conductor, when shorted to ground in any location other than the service is what we call an Edison Loop

What is Neutral

500

L1-Ground reads 220 VAC, L2-Ground reads 10 VAC and Neutral-Ground reads 120 VAC inside a hub inverter in this rare installation mistake.

What is the Neutral is not ran from Service to BUI and is acting as a hot?