112 Starting, Operating, and Shutting Down
209 Inspecting and Testing of Safety Devices
210 Combustible Materials
211 Maintenance, Isolating and Purging
100
Performs remote compressor start-up and shutdown through SCADA.
Who is Gas Control?
100
These are located in compressor stations and compressor vehicles and are inspected monthly.
What are Fire Extinguishers?
100
Check for combustible materials during monthly inspections and remove if found, in accordance with applicable federal safety standards
Who are Compressor Station Personnel?
100
Compressor Station Personnel follow this to close the appropriate valves in order to isolate the compressor.
What is a Work Plan?
200
Performs local compressor start-up and shutdown if remote shutdown fails.
Who is Compressor Station Personnel?
200
Compressor Station Personnel document fire extinguisher inspections by recording inspection information here.
What is directly onto the fire extinguisher tag.
200
Flammable or combustible materials used in compressor buildings for daily operation and maintenance are stored here.
What is approved safety containers?
200
While isolating yard pipe personnel carefully plan all work with this individual.
Who is Supervisor of Compression or Senior Technician of Compression?
300
Compressors are designed to run with the stations in this condition.
What is unmanned and unsupported?
300
Compressor Station Personnel inspect and test fixed fire detection and suppression equipment to determine that it functions properly at these intervals.
What is at least once each calendar year, not exceeding 15 months?
300
Monitor compressor station buildings and facilities to ensure compliance with all federal safety standards concerning storage of combustible materials
Who is Compressor Station Personnel?
300
When a unit or units are ready to return to service, Compressor Station Personnel purge by feeding gas into the compressor through the loading valve and venting out the vent valve for this.
What is at least 60 seconds?
400
This person determines if compressor conditions necessitate a maintenance shut down and notifies Gas Control.
Who is Supervisor of Compression?
400
If equipment deficiency does not allow the system to effect a safe and timely emergency shutdown, these will convene to determine the temporary course of action until the deficiency can be addressed.
Who is Operations Mangers?
400
Compressor Station Personnel store all Class “A” flammable materials in these.
What are covered metal containers?
400
Compressor Station Personnel document this during station blowdown, evacuation, and purging of compressor station piping.
What is gas lost?
500
Gas Control documents local start-up or shut down request here.
What is the Pipeline Remarks Log?
500
Except for these, each pressure relieving device in a compressor station is inspected and tested once each calendar year, not exceeding 15 months.
What is Rupture Discs?
500
Are you feeling Lucky? Well do you punk?
What is a 500 point bonus?
500
A written Work Plan requiring the Isolation of a Compressor Station including specific instructions on station isolation must be approved through this, before commencement of the project.
Who is Engineering – Operations Support, Gas Control, the Manager of Field Operations and the Supervisor of Compression?