Eddy Current
Industrial Services
Air and Water Inleakage Detection
NitroLance
Fouling Mitigation and Mechanical Cleaning
100
The person credited with discovering Eddy Currents
Who is Michael Farraday
100
Chemical plants, refineries, breweries, water treatment facilities, and more are all examples of...
What are CIS Customers
100
Over 6,000 forced outages each year are caused by _________ _____ ______.
What are "condenser tube leaks"
100
An advantage of the NitroLance that saves our customers thousands of dollars in disposal and clean-up costs
What is no secondary waste
100
The HEI method of evaluations looks at performance of the overall tube bundle, while the ______ method looks at the performance of a single tube.
What is Thermal Resistance or ASME
200
The minimum number of frequencies run by Conco during an Eddy Current Test
What is 4 frequencies
200
Bits, brushes, and tube cleaners all work with this Conco Tube Cleaning system
What is the HydroDrill
200
Condenser backpressure climbing, dissolved oxygen levels increasing, and increased usage of phosphates are...
What are indicators of a condenser leak
200
The customizable piece on the NitroLance that penetrates deposits
What is the carrier
200
The amount of tubes that a normal crew can clean during a 10 hour shift
What is 5,000
300
The ______ the probe is pulled, the greater the chance the signal quality may be compromised.
What is "faster"
300
This kind of drill bit is used when cleaning larger tubes
What is a Klaw Bit
300
The tracer gas that is suitable for "most" leaks
What is helium
300
NitroLance can reduce cleaning times for most heat exchanger applications by greater than...
What is 300%
300
The tube cleaner which was created to remove 80 tons of scale and save Clinton Power plant $2.6 million
What is the Calcite Cleaner
400
At a low frequency speed of 24 in./second, ____ samples can be taken each second.
What is "2000"
400
Tube Cleaners range in size from 1/2 in. to ____ in.
What is "1 3/4"
400
The minimum amount of turbine power required for successful leak detection to occur
What is 15%
400
The liquid nitrogen used by the NitroLance cuts through tough deposits at a temperature of...
What is -240 degrees F
400
The tube cleaner which was created to remove 7,000 lbs. of deposit and increase capacity by 25 MW and save Peach Bottom $4.3 million?
What is the Hex Cleaner
500
The amount of time it takes for customers to receive a final report of their Eddy Current Testing
What is 15-<30 days
500
When Conco provides their own power and air, it takes this long to set up the HydroDrill for a job
How long is 2 hours
500
As a result of leak inspection in the UK plant example, vacuum loss was reduced by ~72% and feed water dissolved oxygen was reduced by almost...
What is ~92%
500
The NitroLance can operate at a pressure anywhere between 6,000 psig and _________.
What is 50,000 psig
500
Conco Systems has __ different types of tube cleaners
What is "9"