Air Monitoring
Where do I sign?
Attendant Duties
Emergency
100

The frequency required for bump testing of air monitors

What is daily or prior to the first use of the day

100

To participate in an confined space entry, an Operator must have completed confined space training within this maximum interval of time prior to the entry date.

What is within the past 12 months; confined space training is required annually

100

The measure of elapsed time that necessitates taking an additional set of atmospheric readings

What is thirty minutes

100

This department needs to be called prior to entry and after all personnel have exited the confined space

What is the Lafayette Fire Department

200

The location on the air monitor where the most recent calibration date is recorded

What is on the underside of the metal clip

200

The team member responsible for reviewing the permit and signing off on its completion at the close of a confined space entry

Who is the Entry Supervisor

200

The threshold level for the high temperature extreme triggering additional actions during a confined space entry 

What is 104oF (40o C)

200

The Lafayette Fire Department serves as which member of the site Confined Space Team?

What is the Confined Space Rescue Team

300

The four standard gases for which monitoring is performed during confined space entries

What are Oxygen (O2) Content, Flammability / Lower Explosive Limit (LEL), Carbon Monoxide (CO2), and Hydrogen Sulfide (H2S)

300

This is the required frequency, per OSHA, for reviewing the site's Confined Space Permits

What is annually

300

This must be designated and verified with the Standby Attendant prior to entering a confined space.

What is the communication method

300

The Entry Attendant may only enter the space in the case of an emergency, TRUE or FALSE

What is FALSE; the only exception is if the Entry Attendant duties have been transferred to another Operator prior to the Entry Attendant shifting roles to an Entrant

400

Cargill's minimum and maximum limits for atmospheric oxygen (O2) content during a confined space entry

What is the range of 20% - 22%

400

Three required areas for an Entry Supervisor to review and sign on a Confined Space Permit

Where are:

Training verification

Pre-entry task verification

Job Completion Check / Final Review signoff

400

Three primary responsibilities of an Entry Attendant during a confined space entry 

Ensuring all Authorized Entrants have received confined space training within the specified interval

Controlling access to the space; limiting to Authorized Entrants only

Keeping in contact with Entrants

Recording initial atmosphere readings and additional readings every thirty minutes

Documenting Attendants and Entrants and times on the  Authorized Attendant and Entrant Log

Recording the date and time when all entrants have exited the space at the completion of the entry

400

In the event of an emergency during a Confined Space entry, whose primary responsibility is it to call emergency services?

Who is the Standby Attendant

500

The required calibration frequency for Draeger air monitors

What is every six months

500

Six required areas for an Authorized Attendant to review and sign on a Confined Space Permit

Where are:

Pre-entry atmosphere readings

Training verification

Communication methods / verification

Pre-entry task verification

Continuous Atmosphere Testing log, if entry lasts longer than 30 minutes

Authorized Attendant and Entrant Log

500

This Attendant is not required to be present at the site during a Confined Space Entry

What is the Standby Attendant

500

The plant location where the emergency tripod / winch is stored


Where is the top floor of the Warehouse