Plumbing and lighting
Equipment
Requirements
Layout and design
Definitions
100

Foot-candle requirement for dry storage areas and inside walk-in units.

What is 10 or 108 lux.

100

The type of dishwasher we have in the downstairs kitchen

What is a conveyor machine.

100

Purchase dishwashers that have readable thermometers; increments are no greater than this.

What is 2°F (1°C).

100

According to the book, there are how many areas related to the safe layout and design.

What is 4.

100

Extent to which liquids are absorbed by a material

What is Porosity.

200

Foot-candle requirement for prep areas.

What is 50 or 540 lux.

200

Reach-in units have legs to elevate them at least this from the floor.

What is six inches.

200

Purchase a dishwaser that measures water temperature, pressure, and this.

What is chemical concentration.

200

Designing and arranging these to comply with sanitation standards.

What are equipment and fixtures.

200

Ability of a surface to react to a shock without breaking or cracking.

What is Resiliency.

300

A special type of water heater typically used with dishwashers to heat rinse water to proper sanitizing temperatures. 

What is a Booster heater.

300

Built-in thermometers are easy to read and locate; they are accurate within?

What is ±3°F.

300

Except in areas where food is stored only in unopened original shipping containers, coving shall extend up the wall how many inches.

What is at least 4 inches.

300

Selecting these 3 materials that are easier to clean.

What are wall, floor, and ceiling materials.

300

Curved, sealed edge placed between the floor and wall to eliminate sharp corners or gaps.

What is Coving.

400

An air space that separates a water supply outlet from a potentially contaminated source.

What is an air gap.

400

Floor-mounted equipment must be at least this from the floor.

What is 6 inches.

400

Except in areas where food is stored only in the original shipping containers, what is the minimum radius coving requirement.

What is 3/8 inch.

400

Designing these to prevent contamination and make cleaning easier.

What are utilities.

400

Light intensity is usually measured in units call this.

What is foot-candles or lux

500

A mechanical device that prevents backsiphonage by closing a check valve and sealing the water supply line shut when water flow is stopped. 

What is a vacuum breaker.

500

Tabletop equipment must be elevated at least this from the surface.

What is four inches.

500

Handwashing stations are required in or next to restrooms, and in these three additional areas.

 What is food prep, service, and dishwashing areas.

500

Managing this correctly to avoid contaminating food and attracting pests.  

What is garbage.

500

A physical link between safe water and dirty water.

What is a cross-connection.

M
e
n
u