DC
BASIC DC
CONTROL THE DAMAGE
MORE DC
FAKE FIREFIGHTERS
SHIP DC
100

WHAT IS THE NSTM FOR SHIPS FIREFIGHTING?

NSTM 555

100

WHAT IS THE EFFECTIVE RANGES OF A PKP BOTTLE?

18 LB - 19 FEET 

27 LB - 21 FEET

100

HOW LONG WILL THE OCENO EEBD OPERATE AFTER IT IS ACTIVATED?

10 MINUTES

100

SCBA CYLINDERS SHOULD BE CHARGED TO _______ PSIG.

4500
100

WHAT COLOR IS M-8 PAPER WHEN EXPOSED TO A G SERIES NERVE AGENT? 

RED

100

WHAT ARE THE FIREPUMPS RATED AT?

1000 GPM AT 150 PSI 

LOW 135 PSI 

HIGH 185 PSI

200

WHAT ARE THE THREE COMMON PIPE PATCHING USED IN THE NAVY? 

SOFT, JUBILEE, AND EWARP

200

APPROXIMATELY HOW LONG WILL A 15LB CO2 EXTINGUISHER LAST UNDER CONTINUOUS OPERATION?

60 SECS

200

WHAT IS THE FIRE TETRAHEDRON?

FUEL, HEAT, OXYGEN, AND UNINHIBITED CHAIN REACTION

200

SUBMERSIBLE PUMPS ARE NOT DESIGNED FOR PUMPING WHAT TYPES OF LIQUID?

FUEL/OIL OR HOT LIQUIDS

200

WHAT ARE THREE TYPE OF PORTABLE EDUCTORS?

PERI JET AND S-TYPE, DEBRYSHIRE

200

WHAT WATER MIST SKID COVERS AUX 2?

WATER MIST SKID NR 2.

300

WHAT COLOR IS THE HAND WHEEL FOR AFFF CONCENTRATE?

RED AND BLUE

300

WHAT IS THE PRIMARY PURPOSE OF EDUCTORS?

DEWATER

300

WHAT IS THE RECOMMENDED EXTINGUISHING AGENT FOR A CLASS CHARLIE FIRE?

CO2

300

What is the NSTM for GAS FREE ENGINEER?

NSTM 074 Volume 3

300

WHAT TYPE OF WOOD IS USED FOR SHORING?

YELLOW PINE OR DOUGLAS FIR

300

HOW MANY AFFF HOSE REEL STATIONS ONBOARD?

25
400

WHAT IS THE PURPOSE FOR THE HFP TIME DELAY?

TO ALLOW TIME FOR VENTILATION TO SHUT DOWN AND TO SECURE ACCESSES

400

HOW SHOULD PRIMARY FIRE BOUNDARIES BE SET? 

FOUR SIDES OF THE AFFECTED COMPARTMENT

400

AIR ESCAPING FROM AN AIR TEST FITTING COULD BE AN INDICATION OF WHAT KIND OF DAMAGE? 

FLOODING

400

WHAT IS THE SOAK TIME AND CURE TIME FOR EWARP?

SOAK TIME - 10 SEC

CURE TIME - 30 MINUTES

400

WHAT IS THE MAXIMUM LENGTH OF A SHORE?

30 TIMES THE MINIMUM THICKNESS. 

400

WHAT SYSTEMS DOES FIREMAIN COVER?

AFFF, FIRE STATIONS, FIREMAIN BACK UP FOR A/C 1&3, HPM, VITAL SSDG'S, PULPER, DECON SHOWERS, VCHT, ANCHOR SYSTEM WASH DOWN, SCAC, FM SHORE CONNECTIONS,

500

WHAT ARE THE TWO SIZES OF METAL SHORING UTILIZED?

WHAT IS THE MAXIMUM STRENGTH FOR EACH WHEN EXTENDED?

3-5 FT (12000)


6-11FT (6000)

500

WHATS IS THE STATIC LIFT FOR AN ELECTRIC SUBMERSIBLE PUMP?

70 FT

500

TRUE OR FALSE

OXYGEN LESS THAN 18.5 OR GREAT THAN 24 SHALL BE CONSIDER IDLH

WHAT IS IDLH?

FALSE.

IMMEDIATE DANGER TO LIFE AND HEALTH.

500

WHAT IS THE CHEMICAL NAME FOR HFP?

HEPTAFLUOROPROPANE

500

HOW DO YOU CALCULATE THE TIME IT TAKES TO MAKE AIR CHANGE OUTS FOR A SPACE?

LENGTH X WIDTH X HEIGHT, (CONVERT TO STANDARD FROM METRIC)/ BY MOTIVATOR

EX. (5M X 3M X 10M)*3.2/3200 OR 2000 

500

HOW MANY FIRE STATIONS DO WE HAVE ON BOARD?

WHAT ARE THE CHARACTERISTICS OF THE HOSES IN THE MAIN SPACES AND THE MAIN DECK

52.

ENG SPACES- OUTFITTED 1 1/2 INCH 50 FOOT HOSE AND 95 GPM VARI-NOZZLE

MAIN DECK AND ABOVE - OUTFITTED WITH TWO 1 1/2 INCH 50 FOOT FIREHOUSES AND TWO 95 GPM NOZZLES

M
e
n
u