Lockout Tagout
Confined Space
Fall Protection
Electrical Safety
Forklift Safety
100

What is the reason for Lockout Tagout?

Isolate energy sources for equipment so there is no way that the equipment will accidently start up.

100

When is a confined space classified as entered by a person?

When any part of the person's body breaks the plane to the confined space. 

100

At what height is fall protection required for general industry. 

4 feet. 

100

Can 120 volts be enough to kill a person?

Yes

100

What must be completed before a trained forklift operator can operate a forklift for their shift. 

Complete an inspection

200

Which person is allowed to lockout a piece of equipment because they have been trained and completed hands on evaluation to ensure full understanding of the lockout.

Authorized Team Member / Employee. 

200

What must be completed before a confined space entry is started. 

The entire permit process. 

This includes gathering the participants and reviewing the work and the hazards. Check the atmospheric conditions. Mitigating/Eliminating the hazards. Set up rescue options. And setting up communication methods for all parties. 

200

What is passive fall protection?

A railing meant to ensure that team members cannot fall beyond the railing. 

200

If you find an exposed electrical wire, you must:

Report it immediately to management.

Note* This needs immediate repair.  

200
Can an operator just complete the written test to be certified to operate a forklift? Why?

No. An operator must also pass a hands-on evaluation. 

300

A failure to complete a lockout during cleaning, servicing or maintenance of a machine could result in what kind of discipline. 

Termination

300

Where must the permit be located during a confined space entry? How about the air monitor?

The permit must be located right outside the confined space. The air monitor must be inside the confined space near the entrant. It could also be attached to the entrant via a clip. 

300

What is the OSHA designated rating for a fall arrest anchor point?

5,000 pounds

300

What are the three levels of electrical personnel at Land O Lakes

Unqualified Person

Qualified Person Restricted

Qualified Person

300

What are the required PPE for changing out a propane tank at minimum?

Safety glasses, Neoprene gloves.

Note* If inside the facility, a bump cap, and safety boots would additionally be required. 

400

Locks are on the mechanism in which you are operating. These locks are not yours. Are you able to start working on the device as it currently is? Why

NO! Each person is required to have their locks on the device before working on the device. No exceptions. 

400

What are the three methods of rescue?

Self rescue, non-entry rescue, entry rescue. 

Note, if you are not trained in rescue and the rest of the rescue crew is not present, do not go into the confined space to get the entrant out. 60 plus percent of the fatalities are individuals just jumping in to rescue the entrant. 

400

Name at least 3 ways one can protect themselves from a fall.

Fall Elimination (Bring item down to normal elevation)

Passive fall protection (Railing)

Fall Restraint

Fall Arrest

Administrative Controls (warning line plus attendant on a roof)


400

When unprotected and throwing a lever to a quick disconnect for lockout tagout one must:

Position to the right of the panel. Use their left hand, turn their face away and hold a deep breath before throwing the lever off or on.  

400

What is the name of the sign on the forklift where you can view the weight rating of the forklift?

Forklift Data Plate

500

Name at least 6 types of energy sources.

Electrical, pneumatic, hydraulic, gravitational, steam, chemical, gas, temperature, and mechanical. 

500

What are the three questions to answer to signify if the space is a confined space?

Limited means for entry and exit. 

Not designed for continuous occupancy. 

Large enough and so configured for a person to enter and complete the assigned work. 

500

With the use of a fall arrest system, what is an additional step needed to ensure that a person is protected if a fall occurs. 

Fall rescue plan. 

500

How many times can a qualified person restricted reset a motor control that is exterior of an MCC panel.

Only once.

Note* If it the motor reset trips again, you must contact maintenance. DO NOT reset it again. An internal failure may be occurring that needs to be addressed.

500

You need to load a drop trailer. What are the steps that must be taken to ensure that you are protected when entering the trailer. 

Ensure the trailer is secured either through the use of a dock lock, or combination of chocks and a glad hand (Keep the key of the glad hand in your packet). Install a jack stand under the front of the trailer. Inspect the exterior of the trailer, including underneath to ensure that rafters on not broken (Do not actually crawl under the trailer). With trailer secured, walk into the trailer and inspect the floor boards. If all is good, you may now begin loading the trailer.

Note* If it is found unsafe to load the trailer, do not load and report it to management.  

M
e
n
u