This is the max. allowable clear span shown in detail AD for an embedded strap hold-down.
This detail shows how to splice and hook rebar in foundation walls
What is detail S?
This is the strap we call out at every rafter in detail WJ
What is LSTA24 strap with (12) 10dx1-1/2" nails?
This detail is to replace detail IA in advanced framing situations on the roof framing plan
What is Detail ZA?
In the header off damaged joist detail, this is the max. allowable space we allow between the new joists
What is 12"?
This the detail we provide for retrofit hold-down options
What is detail BN?
Shows how to install a concrete lintel that does not fall under the Utah Amendment to the IBC
What is detail BO?
This is the direction the floor joists are allowed to span in detail IC
What is either direction?
This detail is to replace detail IA on advanced framing situations for the upper floor framing plan
What is detail ZB?
This is the allowable vertical drop in the elevator slab drop detail
What is 24"?
This is the max allowable height above the concrete and max allowable height above the floor system shown in details BC and BD.
What is 18" and 16"?
In detail CW this is what we call out to connect the sill plate to the interior footing
What are concrete nails @ 16" O.C.?
This tension tie is called out in option 1 of detail M
What is the DTT2Z tension tie?
This is the only standard detail of ours that Alpine has it's own custom detail for.
What is detail F?
This detail was recently made into a standard detail but was a very commonly used standard custom detail
This is the number suffix for an HDUE hold-down (J, K, L etc.) is used when using detail BH
What is 2?
In detail IF this is the maximum allowable clear span.
What is 10' for a 6" thick slab, and 13' for an 8" thick slab?
This detail shows how to connect a shear wall that sits on floor joists running perpendicular to the wall
What is detail GR?
This type of hold-down is called out in DR Horton's specifically requested retrofit detail
What is an MST48?
This is the max. span for the self supporting shed roof detail and for what max. snow load?
What is 2'-0" and 40 psf?
This detail is to be used for N and O hold-downs with excessive uplift
What is detail BF?
This is the first letter for all precast panel details
What is N?
This detail shows a rafter/joist ledger attachment to a steel beam
What is detail QA?
True or false: The insulated footing detail has been updated for DR Horton specific projects
What is true?
In the knee brace detail, this mechanical fastener is used to resist the horizontal force induced by the diagonal brace
What is the A35 clip at the top and bottom of the post?