Chapter 5
Chapter 6
Chapter 7
Chapter 8
Chapter 9
100

Any Pressure less than atmospheric pressure is referred to as a

Vacuum

100

What type of fog stream breaks water into fine, evenly divided particles by driving several jets of water together at an angle?

Impinging stream

100

The pump discharge pressure at the apparatus must be enough to overcome:

The sum of all pressure loss

100

What is the equation for determining friction loss in a 3-inch hose using the Condensed Q formula?

FL=Q^2

100

Switching from volume to pressure for a multistage centrifugal fire pump:

Can result in immediate doubling of previous discharge pressure.

200

If Velocity is increased beyond practical limits, the friction becomes so great that resistance agitates the entire stream, and creates:

Critical Velocity

200

Which of the following is customary formula for calculating nozzle reaction for solid stream nozzles?

1.57 x d^2 X NP

200

In order to avoid having two different nozzle pressure when using a wye, it is important that the two smaller attack lines wyed from the supply line are:

the same length and diameter

200

What is the equation for determining friction loss in a 4-inch hose using the condensed Q formula?

FL=Q^2 / 5

200

Which type of priming device uses an oil supply or other type of fluid to seal the gaps between the gears and the case and fill any irregularities in the housing caused by sediment or debris?

Positive displacement primers

300

Stored potential energy available to force water through pipes, fittings, hose and adapters is:

Static Pressure

300

When determining the flow from a solid stream nozzle, which of the following is the constant number in the customary formula?

29.7

300

The metric formula used to determine elevation pressure in a multistory building is:

35kPa x (number of stories - 1)

300

If the volume of water at the nozzle suddenly decreases, but there is no reduction in the flowmeter reading, what is the most likely assumption?

The hose line has burst

300

It is generally recommended that intake relief valves be set to open when intake pressure rises more than:

10 psi (70kPa) above necessary operating pressure.

400

What should the fire department do if there is any question about the reliability of a private water supply system or its ability to provide an adequate amount of water for a large-scale fire fighting operation?

Make arrangements to augment private water supply.

400

Solid stream nozzles on handlines should generally be operated at a maximum of:

50psi (350kPa) Nozzle pressure

400

Formula for determining friction loss

FL=CQ^2L

400

When calculating the required pump discharge pressures for each of the listed layouts on a pump chart, round pump discharge pressure to the nearest:

5psi (35kPa)

400

The total amount of water that can be pumped by a rotary gear pump depends on the speed of rotation and the size of the:

pockets in the gears

500

When a property is served by two sources of water supply for fire protection, municipal system and a private source consisting of nonportable water, why must these systems remain separate?

To prevent cross contamination

500

A rule of thumb for calculating nozzle reation for solid stream nozzle in the customary system is nozzle reaction (NR) equals the total flow of water in gpm flowing through the nozzle (Q) divided by:

3

500

What are two ways to determine friction loss?

Calculations and preforming tests

500

When using a flowmeter for relay pumping, ensure that the incoming pressure does not drop below:

20psi (140kPa)

500

Which pump panel instrument displays engine speed in revolutions per minute?

Tachometer

M