What is the National Electrical Manufacturer's Association?
100
The system on which power travels from the power plant
What is the power distribution grid?
100
Made-To-Order and usually ships in 2 to 5 days.
What is a standard PDU order?
100
Utilizing the full cabinet at 30kW
What is high density?
100
the integration of information technology (IT) and facility management disciplines to centralize monitoring, management, visualization, optimization and intelligent capacity planning of a data center’s critical systems
What is DCiM?
200
IEC
What is the International Electrotechnical Commission?
200
This uses large transformers to convert the generator's voltage for long-distance transmission on the transmission grid.
What is a transmission substation?
200
Provides site managers with power usage, threshold monitoring and historical data all via IP address from the comfort of their desk.
What is a monitored PDU?
200
A cooling device that replaces the rear door of the cabinet.
the purpose of the "extra" wires running along the tops of power towers
What is to ground energy and attract lightning?
300
Can allow a data center professional the ability to capitalize fully on comprehensive power and environmental information by controlling the strip from a remote location.
What is a switched PDU?
300
Fits in a dropped ceiling or can be mounted on a wall
What is a RAC10?
300
An enterprise level monitoring and management system designed to provide visibility across your entire data center’s infrastructure
What is Environet?
400
the ratio of real power(W) to apparent power (VA)
What is the power factor?
400
The place where the conversion of power from "transmission" to "distribution" occurs.
What is a power substation?
400
A key cornerstone to every mission critical data center
What is reliable power distribution?
400
American Society of Heating, Refrigeration, and Air conditioning Engineers
What is ASHRAE?
400
A comprehensive set of products designed to manage rack level data and white space with a single point of integration.
What is Racknet?
500
an electrical switch that switches a load between two sources
What is an Automatic Transfer Switch (ATS)?
500
Increase circuit size, Increase voltage, Increase the number of circuits, Move to 3 phase in the rack
What are the ways to get more power (in a rack)?
500
The standard cord length for one of our PDUs.
What is 10 feet?
500
These are used to exhaust hot cabinet air to the plenum.
What are chimneys?
500
Operational Awareness, Real-Time Gratification and Justification, Convergence of Disparate Systems