Processor Responsibilities and the Quality System
Maintenance
Programs
Grab Bag
Exposure/ Dose
100
Use and comply with a common set of NAVSEA approved SOPs. Perform dosimetry processing with competence, integrity, and impartiality.
What are Dosimetry Processor Responsibilities?
100
Factory/Vendor Maintenance, PMT assembly maintenance.
What is the annual maintenance for the Model 8800
100
Program that takes the raw data from the TLD read file and computes the deep, shallow, and neutron doses by evaluating the ratios from the indicidual chip readings.
What is the Dose Algorithm?
100
Calibration factor for each element of each TLD.
What is the ECC, Element Correction Coefficient?
100
Maximum Effective Range of the DT 702
What is 2000 Rad?
200
Exposure data from personnel dosimetry is essential for minimizing exposure. Radiological controls are confirmed by dosimeter results. Personnel dosimetry has medical and legal significance.
What is the Importance of maintaining the Dosimetry Program error free?
200
Thick Gloves, Apron, Face Shield
What is the safty gear for handling liquid nitrogen?
200
Passes the TLD reader data to the server and controls the operating parameters of the reader.
What is WinREMS?
200
Turn off PMT high voltage after last TLD reading. Notify supervisor and document on reader log.
What are actions to take for Electrical Power Loss
200
Protection Range Calibration.
What is 100 mrem?
300
All the planned and systematic actions necessary to provide adequate confidence that a product or service will satisfy given requirements.
What are QA Guidelines.
300
The period for Cleaning filter glass drawer lenses and electronics QC.
What is Daily?
300
Subtracts applicable background and assigns a dose to a worker to create the final reportable dose of record and maintains historical data.
What is ARCMIS?
300
Gaussian-type bell curve with 1 peak approximately centered in the graph.
What is a normal glow curve.
300
Accident Range Calibration
What is 1000 mrem?
400
The operational techniques and activities that are used to fulfill requirements for quality assurance. Focus on standardized systems, procedures, training, and verification by inspection.
What are QC Guidelines?
400
Action to take if there is a major leak of nitrogen gas/liquid or an oxygen monitor alarms.
What is evacuate the space, and notify supervision?
400
Defines the operating conditions of the TLD read, threshold, warning levels and data storage format.
What is the Acquisition set-up?
400
Eliminates low temperature peaks. 10 seconds at 165 C.
What is the preheat phase of the TTP?
400
Quarterly NAVSEA Limit for Radiation Workers
What is 3000 mrem?
500
Use of good design principles so that the entire measurement process; its components, and relevant influence factors can be well-characterized, monitored and controlled.
What is Measurement Assurance
500
Confirms that the instrument's electronics are operating within specifications.
What is the EQC Check?
500
Controls the mechanical functions of the reader and transmits the TLD reader data to the WinREMS computer.
What is teh Embedded Controller?
500
African or European?
What is the air-speed velocity of a coconut laden swallow?
500
The Exposure of TLDs for NIST Traceability Testing
What is 500 mrem?