X-ray Production
Digital Imaging Systems
Fluoroscopy Equipment
Beam Restriction & Grids
Equipment Troubleshooting
100

Approximately what percentage of electron energy becomes x-rays?

What is less than 1%

100

The brightness of a digital image is primarily controlled by this factor

What is rescaling/processing

100

Fluoroscopy provides imaging in this format.

What is real time?

100

The primary purpose of collimation is to reduce this.

What is scatter radiation?

100

Exposure indicator values consistently lower than expected suggest images may be this.

What is underexposed?

200

The majority of x-rays useful for imaging are produced by this interaction.

What is Bremsstrahlung radiation

200

 The number of shades of gray displayed is controlled by this parameter.

What is window width?

200

 This device converts x-rays into visible light and electronic signals.

What is an image intensifier?

200

 Grids improve image contrast by absorbing this.

 What is scatter radiation?

200

A damaged detector may produce this type of image artifact.

What is a line artifact or dead pixel artifact?

300

Characteristic radiation occurs when electrons interact with this electron shell

What is an inner shell electron

300

This parameter determines image brightness in display processing.

What is window level?

300

Pulsed fluoroscopy helps reduce this.

What is patient radiation dose?

300

 The lead strips in a focused grid are angled toward this location.

 What is the focal spot?

300

Failure of the rotor may prevent this anode movement.

What is rotation?

400

Increasing kVp increases both x-ray quantity and this beam property

What is beam quality (penetration)

400

Smaller pixel size generally results in improved ______ resolution.

What is spatial resolution?

400

The foot pedal primarily controls this during fluoroscopy.

What is x-ray production/exposure?

400

 Increasing grid ratio improves contrast but requires more of this.

What is patient exposure (mAs)?

400

Regular calibration ensures equipment maintains this characteristic.

What is accuracy?

500

This layer of the x-ray tube housing absorbs low energy photons

What is filtration

500

Excessive exposure that is masked by image processing is known as this phenomenon.

What is dose creep?

500

Last-image hold improves efficiency while reducing this.

What is radiation exposure?

500

 This error occurs when the wrong SID is used with a focused grid.

What is off-focus grid cutoff?

500

Consistent QA testing helps ensure compliance with these requirements.

What are regulatory standards?

M