Signatures
Form Rules
Section A
Section B/C
Section G
Section H
Wild Card
100

Who can complete Section C?

Any licensed surveyor, engineer or architect.

100

Are ECs required to participate in CRS?

Yes

100

What's new in Section A on the 2023 form?

A5, A6, some A8/A9 fields

100

Do both Comm Name and Comm # need to be correct?

Yes. They are separated now.

100

Is Section G mandatory?

It is under the new form.

100

Is Section H mandatory for CRS?

No

100

Why are ECs required in CRS?

Show compliance - Class 9 prereq

200

Who can fill out Section E?

Anybody

200

Starting when...must the new form be used?

November 1, 2023 (or July 7, 2023)

200

Why is Lat/Long important now?

Insurance now geo-locates all policies.
200

Why important to show elevation of attached deck/stairs?

It might place the building in a flood zone

200

Who has to sign Section G?

Local official (any staff?)

200

What new diagrams come with Section H?

Foundation Type Diagrams.

200

First place to look when learning how to fill out EC?

The EC Instructions

300

Who fills out and signs Section G?

Local Officials

300

3 purposes of the EC form?

Compliance, Mapping and Insurance

300

What has replaced the Building Diagrams now in A7?

Nothing - they are still used.

300

When are ECs required for CRS purposes (construction stage)?

Finished Construction

300

What fields are mandatory with new form?

G8 and G11 (and Name, Signature & Date)

300

Define "First Floor Height".

First floor at or above grade (LAG).

300

Section E recently added what (taken from Section C)?

Stage of Construction fields.

400

What Sections can a local official fill out?

Sections A, B, E, G and H.

400

Must an EC be used for insurance now?

No and Yes

400

Why A6 (Photos) now?

First Floor Height and they really help 

400

Does "Natural" or "Finished" grade matter?

No and Yes

400

Can local officials correct the EC using Section G?

Yes - as long as it's not an elevation.

400

What M&E is used for the Mitigation Discount?

A/C Unit, Furnace, Water Heater, Heat Pump, Elevator - Building. Washer/Dryer and food freezer - Contents

400

Is an A99 Zone considered SFHA?

Yes, but it has no flood depth or BFEs.

500

Who fills out Section H?

Anybody.

500

Are ECs used to place buildings on the NVT list?

Yes - when they come in with CRS reviews

500

Why new question for A8b/A9b?

TB1 suggests this standard, but it is not in 60.3.

500

Why are datum conversions needed?

Talk apples to apples

500

How can you correct an outdated EC using Section G

Select G1 and do what it says.

500

Why was Section H created?

To help defer costs of an EC when seeing if EC helped with rating/premium.

500

Att Gar & Enclosures - what's the deal?!