Sensors & controls
Dampers & Actuators
Economizer Logic
Troubleshooting
Maintenance & Inspection
100

What sensor measures outdoor air temperature for economizer operation? 

Outdoor air temperature sensor 

100

Which damper brings in outdoor air?

Outside air damper 

100

When does an economizer provide free cooling?

When outdoor air is suitable (cool/dry)

100

Economizer stuck closed is a likely cause of what?

Failed actuator or control signal 

100

How can you verify damper rotation is correct?

Measure position with a gauge or visually inspected linkages

200

What does an enthalpy sensor measure?

Total heat (temp+humidity) in the air

200

Purpose of the minimum position setting?

Maintains ventilation airflow 

200

If outdoor temp is higher than return temp, what happens?

Dampers close, mechanical cooling runs. 

200

Economizer stuck open on a hot day is likely a cause of what?

Sensor/module failure or linkage problem. 
200

How often should economizer sensors be cleaned?

At least annually or per manufacturer recommendation

300

A CO2 sensor can be tied in an economizer

TRUE

300

If an actuator fails, what damper position is safe?

Closed or minimum position 

300

What’s mixed air temperature supposed to be maintained at?

Around 55 degree F supply air

300

If mixed air is too hot, what might be wrong?

Outside damper is stuck open? Possibly parameter setting.

300

What tool can check if the actuator torque is sufficient?

Torque meter or manufacturer specified wrench.

400

Which controller decides if the economizer opens or mechanical cooling starts?

Economizer control module 

400

Two types of damper actuators?

Spring return, non Spring return or (pneumatic/electric)
400

What’s the “high limit“ control in economizers?

Temp/enthalpy limit where outdoor air is no longer efficient 

400

CO2 levels stay high- economizer not helping, what can be the cause?

Minimum position not set, damper, not opening

400

Why inspect damper linkages?

To ensure smooth operation and avoid sticking or binding

500

Difference between dry bulb and enthalpy economizer control?

Dry bulb= temperature only 

Enthalpy= temp+humidity 

500

Effect of misadjusted linkage?

Dampers don’t fully open/close, poor control. 

500

Why is economizer lockout needed? 

Prevents economizer use in extreme hot/cold or humidity conditions?

500

Damper keeps hunting open close rapidly what are the likely causes?

Faulty sensor or control calibration

500

How do you verify an entropy sensor is reading correctly?

Compare sensor reading to non-outdoor temp and humidity or calibrated psychrometer