True or False. a bent armature shaft will cause the solenoid not to work.
What is false
100
There are usually six of these inside of an AC generator.
What is diodes
100
This is the first thing you should do before performing any test on a charging system.
What is visual inspection.
100
This prevents the armature from spinning too fast
What is the overrunning clutch
200
The battery, rotor and voltage regulator are components of this circuit in the generator
What is the field circuit.
200
When checking the rotor on an AC generator the test you should do are
What is checking for opens, shorts and grounds.
200
Testing positive battery cable and terminal. not the battery post. voltage drop is too high. the proper repair is.
What is replace the cable and terminal
200
The stator outputs this in an AC generator
What is Current
200
This is not a stationary component of a starter.
What is the armature.
300
Increasing current flow and coiling more wire around it's core will make this stronger.
What is magnetic field
300
When checking a generator this test could damage electronic components such as an ECM.
What is disconnecting the battery with engine running.
300
You are testing this system, you check the battery,then test voltage drop on the pos. side, then on the neg. side the system you are checking is.
What is the charging system.
300
This is a three phase winding.
What is the stator.
300
Battery and cables, drive belt, wiring and connectors are part
of this system.
What is the charging system
400
The voltage regulator controls this in the AC generator.
What is voltage only.
400
Diodes are used for this function in an AC generator.
What is rectify current
400
This has an electromagnetic field, is used on a starter motor and does a mechanical job.
What is a solenoid
400
DC voltage is present at this large terminal on the generator.
What is the battery terminal
400
This component carries magnetic field current in the generator.
What is the rotor
500
This transmits torque and prevents overturning of the armature.
What is the overrunning clutch.
500
Open windings, bad armature or broken brushes, will this cause.
What is starter not working
500
Low battery, poor solenoid contacts and/or bad cable connections with the key in the crank position will cause this.
What is a rapidly clicking solenoid
500
A starter test being performed 12 volts is found between both large contacts on the starter when the ign. switch is turned to the start position and a click is heard. What could the problem be
What is a defective solenoid
500
Visual inspection,Battery condition,Starter draw and voltage drop is
What is the correct steps for checking a starter system.