DC Theory
Safety
Canadian Electrical Code (code book allowed)
Wiring Installations
All subjects
100

The formula to calculate the total resistance of resistors connected in series is:

RT = R1 + R2 + R3......

100

To protect your eyes from flying objects and shrapnel throughout the regular work day, what PPE must be worn?

What is safety glasses.

100

Load of lighting and receptacle circuits, based on the outside dimensions of a specific area of building occupancy, as listed in Table 14

What is Basic Load
100

A portion of a circuit where the point of control is wired after the device it is controlling.

What is switch loop.
100

Safety

Death caused by exposure to electricity

What is Electrocution

200

The measure of a materials ability to become magnetized.

What is permeability.

200

Who may remove a lockout lock? 

The person that installed it.

200

The receptacle configuration for an electric range installed in a dwelling unit. 

14-50R - 26-744(4)

200

To provide ground fault protection to a receptacle after a GFCI receptacle, it must be wired to which terminals.

Load terminals.

200

Code

Suitable marking tape shall be buried halfway between an underground installation and grade level.

12-012(11)

300

Given values for current and resistance. The quickest formula to solve for power. 

P = I2 x R

300

Two symbols that must be found on work boots. 

What is CSA - green triangle

            Ohm Symbol - Orange

300

Receptacles rated 30A or more and installed facing downward shall have provision for locking or latching to prevent unintentional detatachment. 

26-700(6)

300

To control a light from 2 locations, what type of switching is used?

What is 3-way switching

300

AC Theory

A resistor and an inductor are connected in series. R=80 ohms. XL=25 ohms. Calculate total impedance. 

Z=83.81 ohms

400

A variable resistor with 2 terminals.

What is rheostat

(Delmars 7th edition pg 117)

400

The correct lean angle for an extension ladder. 

4:1. 1 foot out for every 4 feet up.

400

What demand factor shall be applied to an electric furnace for the purpose of residential service calculations?

100% - 62-118(4)

400

A ground fault circuit interrupter will trip at _____ of current to ground. 

4 - 6 mA

400

DC Theory

Either metal or non-metals that cannot be magnetized.

What is Diamagnetic.

500

A 3 band resistor has the colour code Brown, Blue, Blue. What is the resistance and tolerance?

16 mega-ohms plus or minus 20%

500

The additional PPE required to operate an abrasive cut-off saw or angle grinder.

What is face shield.

500

Dryer and Range cables are for use in household dryer and range power supply cords only. Are these cables permitted to be sold to the public for general use. 

No - 12-402(1) T-11 Note 2

500

A device which must be wired to an un-switched lighting circuit. Mounted 14" down from the ceiling. 

What is smoke alarm. 
500

Code

Is it necessary to install a receptacle in the organ loft of an electrically operated pipe organ?

Yes - 26-900(2)