Electrical theory
Electrical tools
Electrical test equipment
Electrical drawings
NEC rules
100

 Any electrons located in the outer shell of an atom are known as ____ electrons.

Valance

100

A drill bit with a spiral cutting edge used to bore holes in wood is called a(n)_______ bit.

auger

100

 A(n) __________ can indicate that voltage is present on a circuit without actually being connected to the circuit.

non contact voltage tester

100

The __________ is a drawing that shows building detail from a view directly above the house.

floor plan

100

When holes are bored through wood framing members for the purpose of installing an electrical cable, the holes must be bored so the edge of the hole is not less than __________ from the nearest edge of the wood framing member.

1 and 1/4 inch

200

A ____ is generally made from material that contains one or two valence electrons.

conductor

200

A hammer used by an electrician should have __________ claws.

long and straight

200

 A meter that uses a moving pointer or needle to indicate a value on a scale is called a(n) __________ meter.

Analog

200

A(n) __________ shows the side of the house that is facing a certain direction.

elevation drawing

200

Where the opening to an outlet, junction, or switch point is less than 8" in any dimension, each conductor must be long enough to extend at least __________ outside the opening.

3 inches

300

 Electrical ____ is the flow of electrons.

current

300

 Another name for a 'Skilsaw' is a __________ saw

circular

300

 An instrument used to measure values of resistance is called a(n) __________.

Ohmmeter

300

Most residential plans are drawn on a scale of __________ = 1'.

1/4"

300

 Lighting fixtures, weighing no more than __________, are permitted to be supported by outlet boxes.

50 pounds

400

The ____ is a measurement of the amount of electricity that is flowing through a circuit.

ampere

400

 Another name for a 'Sawzall' is a __________ saw.

reciprocating

400

. A(n) __________ is the circuit conductors between the final overcurrent device and the outlets.

branch circuit

400

 If a blueprint is drawn with a scale of 1/8" = 1', a line 1 inch long will equal __________ on the blueprint.

8 feet

400

Receptacles must be installed so that no point measured along the floor line in any wall space is more than__________ feet from a receptacle.

6 feet

500

A conductor connected to the case of an appliance to provide a low-resistance path to ground is called a(n) ____ conductor.

grounded

500

 __________ are used to cut cables and conductors in a limited space.

diagonal

500

Electrical power is measured in __________

watts

500

On construction sites, all 120-volt power tools must be plugged into a(n) __________.

ground fault circuit interrupter receptacle

500

The required wall receptacle in each bathroom of a dwelling unit must be installed adjacent to, and within__________ of the sink. (General Rule)

36 inches