Safety and Math
DC Fundamentals
Canadian Electrical Code
Wiring
Random
100

What does NRR stand for?

Noise Reduction Rating

100

A resistor used when a high power rating is required.

Wire wound resistor.

100

Trade size 91 mm conduit in inches?

3 1/2"

100

At what distance from a box shall the first support for an NMD90 cable be located?

*Double Points if code rule stated - 2 minute time limit*

Within 300mm (or 1 foot) 

12-510(1a)

100

As little as _______ milliamps can be lethal.

15

200

List 5 damaging effects of an arc flash on the human body.

Burns, eye damage, internal damage, shrapnel in the body, hearing damage.

200

A measure of charge.

A coulomb

200

Shall non-current carrying conductive parts of electrical equipment be connected to a bonding conductor?

Yes 10-600(1)

200

Draw the line diagram for a circuit wired with a switch, light and receptacle in that order.

--|l-- Switch --|ll-- Light --|l-- Recep.
200

What is the receptacle configuration for a range receptacle in a dwelling unit?

14-50R 26-744(4)

300
What is your last line of defense in an arcing incident?

PPE

300

State the colour code for a 350 kilo-ohm resistor with a 2% tolerance.

Orange, Green, Yellow, Red

300

In dwelling units, receptacles shall be installed in finished walls of every room so that no point along the floor line is more than __________ from a receptacle.

1.8 m

300

The constant power wires closest to the breaker go to which side on a GFCI receptacle?

Line side

300

What are the 3 systems used to measure magnetic values?

English, SI, CGS

400

What tool is used to verify absence of voltage?

Voltmeter or Multimeter

400

List 3 examples of Diamagnetic Metals.

Copper, Brass, Antimony

400

Shall audio amplifiers for transmitters be suitably housed and ventilated?

Yes, 54-1006

400

What is the red wire of a smoke alarm for?

Communication, if 1 smoke alarm is set off, they are all set off.

400

In a box fill calculation, what is the space taken up by a #10 insulated conductor?

36.9 mL 12-3034(4)

500

A conduit has an inside diameter of 2", and an outside diameter of 2 5/16". Find the Wall thickness.

5/32"

500

3 resistors are connected in series. RT = 400 ohm, R1 = 75 ohm and R2 = 135 ohm. Solve for R3

R3 = 190 ohm

500

Can NMD90 be installed in a cable tray?

No 12-102(3) T-19

500

A method of controlling a light from more than 2 locations.

4-way switching

500

If 75 coulombs pass through a resistor in 3 seconds, and the resistor is connected to a 275 V source. State the colour code of the resistor with a 1% tolerance.

*DAILY DOUBLE*

Brown, Brown, Black, Brown

M
e
n
u