1.2m 12-114(1b)
Draw the symbol for an inductor.
Delmars pg 421
The CSA configuration for a standard 120v, 15A receptacle.
5-15R
How long is Milwaukee's battery warranty?
2 years
Convert from Polar to Rectangular 50 < 25 degrees.
45.31 + 21.13i
What CSA configuration is required for an attachment plug for a 120/240 V free-standing electric range in a residential dwelling unit?
14-50P 26-744(7)
If frequency is 50 Hz, and inductance is 0.053 H, calculate inductive reactance.
16.65 ohms
This device is required to be used as a pair, and they control an electrical load from 2 locations.
3-way switch
Other than a trigger lock, this subtle feature can be found on every battery operated Milwaukee tool.
Light/ Work light/ LED
In a pure inductive, how many degrees are current and voltage out of phase with each other?
90 degrees
What is the maximum number of outlets allowed on a 15A 2 wire branch circuit where the fused switch or circuit breaker is marked for continuous operation at 80%?
12 outlets 8-304(1a)
Given a total opposition to current flow of 225 ohms, and resistance is 100 ohms, find capacitive reactance.
201.55 ohms
What is the spacing between supports on a 14/2 AC90?
1.5 m 12-618(1)
What is the minimum arc flash boundary?
4 feet
Determine the resistance value of a resistor with a colour code of brown, green, red, silver
1500 ohms +/- 10%
Yes 26-206
Calculate XL with the following information: Q = 3.5
R = 20 ohms
70 ohms
10, 22, 30, 45, 60
Other than the standard PPE, what additional PPE may be required when operating a Rotary Hammer. 2 items.
Hearing Protection and Dust Mask
Is a switch an outlet?
No - outlet definition sec 0
What is the minimum size of copper grounding conductor?
#6 10-114(1a)
A sine wave representing an AC current, has a value of 18 A at 12 degrees. What is the value at 90 degrees?
86.57 A
Name the parts of a conduit bender. 5 items.
Foot pedal, hook, shoe, markings on the shoe, bender handle,
The first step to replacing bits/blades on any power tool.
Remove battery or unplug/ disconnect power
Where fixed multi-outlet assemblies are used, how many outlets shall be counted for each 1.5 m or fraction thereof for each continuous length where devices are not likely to be used simultaneously?
1 outlet 8-304(4)