Compressor
Condenser
General
Metering Device
Evaporator
100

The main goal of a basic refrigeration system is to ____________ temperature in an area by removing ____________ from it. 

Lower   Heat

100

In the Condenser, the refrigerant ________ Heat.

Rejects

100

True or False

"Change of State" is another way of Saiyan "Phase Change".

True

100

At the Metering Device, the refrigerant enters as a high pressure, high temp liquid and exits as a low pressure, low temp _______.

A. Vapor                        B. Solid

C. Liquid                        D. None of the Above.

C. Liquid.

100

At the Evaporator, the refrigerant enters as a low pressure, low temp liquid and exits as a low pressure, low temp ________________.

A. Superheated Vapor     B. Superheated Liquid

C. Subcooled Liquid        D. Subcooled Vapor

A. Superheated Vapor    

200
At the compressor, the refrigerant enters as a low pressure, low temperature superheated _______ and exits as a high pressure, high temperature, superheated _______.

Vapor     Vapor

200

At the condenser, the refrigerant enters as a high pressure, high temperature superheated vapor and exits as a high pressure, high temperature, _______ liquid.

Subcooled

200

True or False

During the phase change, the refrigerant is in the saturated state.

True

200

Installed on the Liquid Line to trap any water and debris from flowing through the system.

What is "Filter Dryer"

200

Superheat occurs when the refrigerant gains heat after it has changed from a saturated state into a ________ state.

A. Vapor                        B. Solid

C. Liquid                        D. None of the Above.

A. Vapor  


300

What pressurizes vaper refrigerant?

Compressor

300

___________ occurs when the refrigerant loses heat after it has changed from a saturated refrigerant to a liquid.

A. Superheating             B. Total Superheating

C. Subcooling                D. Saturation

C. Subcooling

300

Changes the direction of the refrigerant flow in a system

Reversing Valve

300

Comprised of a large vapor tube and a small liquid tube.

What is "Line Set"

300

Where the refrigerant absorbs heat and changes to a vapor.

Evaporator Coil

400

Allows the flow of refrigerant to be shut off for servicing and provides an access to read system pressures.

A. Ball Valve              B. Service Valve with Port

C. Schrader Valve      D. None of the above.

B. Service Valve with Port.

400

A tank that protects the Compressor by only allowing vapor refrigerant to enter the suction side of the compressor.

Accumulator.

400

Both liquid and vapor exist at the same moment, in the same location.

Saturated

400

A restriction that causes the refrigerant to reduce in pressure in order to expand: can be fixed or regulating.

What is "Metering Device"

400

The temp increase of vapor refrigerant above its saturated temp.

Superheat.

500

Explain what the role of the compressor has in separating the high and low sides of a system.

At the compressor inlet there is low pressure, low temp, superheated vapor and at the compressor outlet there is high pressure, high temp, superheated vapor.

500

Explain what the role the metering device has in separating the high and low sides of a system.

Metering devise inlet has high pressure, high temp, subcooled liquid and the outlet has low pressure, low temp, subcooled liquid.

500

Where the refrigerant rejects heat and changes to a liquid.

Condenser Coil.

500

How is a regulating metering device such as a TXV different than a piston metering device?

A TXV reduces or enlarges the orifice size depending on the heat load of the evaporator.

A piston is a fixed orifice.

500
What is the temp decrease of liquid refrigerant temp below its saturated temp.

Subcooling.