Network
LXC
LXP
LXO
Pedestal
100
Fibre Telecom Network

What does FTN stand for?

100

Level crossing control

What does LXC stand for?

100

Level Crossing Power

what does LXP stand for?

100

In the signal box/interlocking room

where will the LXO be located?

100

230V

What voltage runs the motor inside the pedestal?

200

Cisco Edge

Which network switch will be located in the LXO/Interlocking cabinets at the signal box.

200

a 48 Core cable to the LXIF

what size cable will be used between a LXC/LXIF

200

48V DC

what voltage are the Batteries within the LXP supplying?

200

level crossing office

what does LXO stand for?

200

175V

what I the S&T safety limit for working on live voltage?

300

To provide data  transmission, and to provide the system with complete diversity.

What is the purpose of the FTN system?

300

D1 and D2

which two outputs are used by the ElectroLOGixS to call the barriers to raise or lower?

300

Inverter, Rectifier and battery strings

which components can be hot swapped in the LXP?

300

1 slot chassis

which chassis size will be located within the LXO

300

2nd and 4th Proximity sensors lit

When the barriers are raised which proximity sensors will be lit

400

Nothing will happen as the system has complete diversity

what will happen if a fibre cable is cut between two location cases?

400

All outputs will become de energised

what will happen to the outputs of a VLD for it to achieve a "failsafe" state?

400

4 core plug coupled cable

which type of cable connects the LXP to the Pedestal?

400

Used for non vital controls

What is the RSTi being used for in the in the signal panel?

400

At a period set out by the manufacturer

at what interval should an oil change be carried out within the pedestal?

500

a network switch failure

what would cause a loss of transmission to an entire location case.

500

Module version and SSR count

what two things should be considered when changing a VPM3

500

LXC, LXIF, Pedestal

What does the LXP supply power for?

500

ST 5444

Which RSTi slice requires configuration?

500

Controlled by the ABB inverter

Which component controls the speed at which the barriers operate?