What is the max amount you can spend using petty cash?
$1000.00
100
Per Vol 11 What would be an example of Light frame construction?
1-4 stories Residential, stores, businesses, and light manufacturing.
100
How wide are main isles in malls?
20'
100
The minimum temperature a substance needs to be heated to cause self sustained combustion independent of a heating source is called?
Igniton temp
100
The four major responsibilites of the fire ground commander are:
1. Firefighter safety
2. protect and remove, and provide care for endangered occupants.
3. stop the fire
4_______________
4. Conserve property during and after fire control operations.
200
What amounts do you need prior authorization for?
amounts over 150.01
200
Per Vol 11 what type of consturction would be a High Rise hospital like HGH?
Heavy floor
200
What is the minimum width of cross isles in malls?
15'
200
In the Health category of the 704 system the number 3 would indicate that the material is___________ and can be entered wiith what protection?
Extremely hazardous but can be entered with full ppe scba and bands.
200
The fire ground operation is not over until the FGC has performed a______________
Post fire critique
300
What signatures must you have for approval on a purchase from $500.01 to $1000.00?
FC, CD or Deputy director and FMD
300
According to IFSTA, what type of construction is a residential house?
Type 5 Wood frame
300
Who is the department coordinator for knox boxes?
B.C. of fire prevention
300
Water may be used to blanket a fire and accomplish extinguishment if the flammable liquid has a specific gravity of _______________
1.1 or heavier.
300
The Fire Attack plan is based on three tactical priorities that will establish the major tactical activiites, they are?
1. Rescue
2. fire control
3. property conservation
400
Who must sign for all computer equipment?
IMD
400
According to Vol 11, what type of construction also includes Heavy timber?
Heavy Floor
400
How far apart are hydrants spaced in residential neighborhoods?
600'
400
A number of 2 in the flammability section of the 704 system indicates?
Material must be moderately heated before ignition will occur , water spray may be used to extinguish or cool below flash point.
400
According to Command book, a practical span of control is?
3-5
500
For purchases from $150.01 to $500.00 what prior authorization do you need?
MMD unless it is for an emergency and the IC has approved.
500
According to IFSTA what type of construction is concerned with fire running in void spaces?
Type 3, ordinary construction.
500
How deep should water piping be buried for auxillary water systems?
24" and 36" for vehicle traffic
500
A 3 in the Reactivity section of the 704 system would indicate that the material may____________ and fire fighting should be done from_________________distance.
may detonate and fight fire from a explosive protection distance.
500
What position should ladders be put into if they are not needed for offensive attack?