Core

Type 1
Type 2
Type 3
Ozone
100

The bubble point is...

the value of when a mixture has hit subcooling (liquid).

100

Are there drop-in refrigerants, substitutes such as for R-22.

No.

100

How should multiple relief valves be installed?

Parallel 

100

A hydrostatic tube test kit performs this task.

What is testing for a tube leak?

100

The meaning of ODP.

What is Ozone Depletion Potential?

200

The dew point is...

the value of when a mixture has hit superheat (vapor).

200

A recovery tank should not exceed this capacity.

What is 80%?

200

what does a moisture-indicating sight glass indicate?

Moisture

200

These are considered to be 'major repairs.'

What is replacing the compressor, condenser, or evaporator?

200

The meaning of GWP.

What is Global Warming Potential?

300

Azeotropic mixtures are...

What are two mixtures containing 2+ refrigerants that act as one compound?

300

When handling a charging cylinder filled with refrigerant, what must you do?

What is recovering the vented off refrigerant?

300

What can an owner do to extend the repair deadline of a leaking appliance?

shut down appliances and recover refrigerant from isolated systems or whole systems. 

300

The liquid refrigerant is charged into the stem through what?

What is the evaporation charging valve?

300

This refrigerant category has the highest GWP

What is CFC?

400

Zeotropic mixtures are... 

mixtures of components that have different boiling points.

400

These should be installed when recovering refrigerant from a household refrigerator.

What are low and high-side access valves?

400

How long does the owner have to retrofit or retire a leaking appliance if the replacement/retrofit is an exempt refrigerant?

18 Months

400

This should be circulated through a chiller while recovering refrigerant to prevent it from freezing.

What is water?

400

The amount a single chlorine atom can destroy.

What is 100,000 ozone compounds?

500
Temperature glide is...

What are different pressures for the same saturation temperature?

500

When the compressor is inactive, how much refrigerant must the equipment recover?

80% of refrigerant or a 4-inch vacuum.

500
These are the maximum leak rates for various systems per year...

What is 10% for comfort cooling, 20% for commercial refrigeration, and 30% for IPR?

500

A 350-ton R-123 chiller at 0 psig has how many pounds of refrigerant in the vapor state?

What is 100 pounds of refrigerant?

500

This compound forms if chlorine comes in contact with ozone.

What is Chlorine Monoxide?