Core
Type 1
Type II
Dates
Type III
100

An ozone molecule is made up of blank

What is 3 oxygen atoms

100

When filling a charging cylinder with a refrigerant, the refrigerant that is vented off the top

What is must be recovered

100

The evaporation temperature of R-410a at 130 psig is

What is 45 degrees fahrenheit

100

If using a recovery machine after this date you must evacuate the unit to 0 psig

When is November 15, 1993 

100

During chiller evacuation water is circulated to prevent

What is the freezing of water

200

How many microns are needed to reach dehydration?

What is 500 microns

200

The process of removing refrigerant from an appliance and storing it in an external container

What is recovery

200

If an appliance with 50 or more pounds of regulated refrigerant has exceeded the threshold leak rate, the equipment owner or operator has 

30 days to repair the appliance so that it leaks below the threshold limit
200

What was the CFC phase out date?

When is December 31,1995

200

What requires purge units because they operate below atmospheric pressure

Low pressure chillers

300

A refillable refrigerant cylinder must never be filled more than what percent of its capacity by weigh

What is 80%

300

If a technician suspects that the refrigerant in a recovery cylinder to be contaminated, what should be done?

What is, the technician should check pressures and compare it to the PT chart

300

When under a deep vacuum the motor winding of a hermetic refrigeration compressor will be damaged if

What is energized

300

As of what date is it illegal to vent Class I and CLass II refrigerants into the atmosphere?

When is July 1st 1992

300
Before disposing of a low-pressure appliance, the refrigerant must be recovered or evacuated to 

What is a 25 mm og Hg absolute


400

____ Values are used for charging by suction or evaporator superheat

What is Dew Point (Vapor)

400

When retrofitting or converting a system to use a different refrigerant, only what can be used?

What is only EPA-approved substitutes (Remember there is no such thing as a "drop-in" substitute. 

400

What is the charge per year when used for industrial process refrigeration?

What is 30%

400

As of January 1st, 2019, what is the applicable maximum leak rates of a commercial refrigeration system?

What is 20% of the charge per year

400

If a chiller with a charge of 200 pounds of an ozone depleting refrigerant has passed the initial verification leak test, a follow-up verification test must be conducted within ___ 

What is 10 days

500

A single chlorine atom can last in the stratosphere for ____ years and destroy upto _____ ozone molecules?

What is 120 

What is 100,000

500

When using a passive system dependent recovery process you should access both the high and low side of the system for the refrigerant recovery if

What is when the compressor is not energized

500

What is the required level of recovery for a high pressure appliance?

What is 10" Hg

500

What date was the sale of CFC's and HCFC's restricted to technicians in refrigerant recovery?

When is November 14,1994

500

When recovering equipment from a low pressure chiller, to what should it be heated in temperature as less refrigerant will be contained in the oil at higher temperatures?

What is 130 degrees