100

What is the significance of an azeotropic mixture?

The mixture combines to act like a single-component refrigerant

100

CFCs are more likely to reach the stratosphere than other chlorine-containing compounds because _____________.

they are chemically very stable

100

Recovery equipment manufactured after November 15, 1993 that is used during the maintenance, service, or repair of small appliances must be certified by_________

an EPA-approved third party

100

In a high-pressure system, one indicator that there is a leak in the system is _______.

Excessive superheat

100

The component that changes a low-pressure vapor to a high-pressure vapor is the

compressor

200

HCFC refrigerants cause _______ damage to the stratospheric ozone layer in comparison to CFC refrigerants.

less

200

Positive evidence that CFCs are in the stratosphere comes from __________

 measurements of CFCs in air samples taken from the stratosphere

200

is the process of removing water and water vapor (moisture) inside a system.

Dehydration

200

Hydrochlorofluorocarbon refrigerants contain_____________.

hydrogen, chlorine, fluorine, and carbon

200

A constant purging of a low-pressure unit is an indication of

A system leak

300

All persons opening appliances for maintenance, service or repair must have at least one piece of certified, self-contained recovery equipment available at their place of business. The only exception is for ___________.

small appliances

300

 Technicians are certified to recover refrigerant during the maintenance, service, or repair of high-pressure equipment if they receive a passing grade on the...

Type II exam

300

Refillable cylinders are referred to as_________ 

Recovery Tanks

300

Since what date has it been illegal to knowingly release CFC and HCFC refrigerants during the service, maintenance, repair or disposal of appliances?

July 1, 1992

300

A refrigerant unit using an open compressor that has not been used for several months, is likely to leak from the

rotating shaft seal

400

________ requires chemical analysis of the refrigerant to verify that the ARI 700 Purity Specification are met.

Reclamation

400

Recovery devices that can capture liquid and/or vapor refrigerant without the assistance of components in the air conditioning or refrigeration equipment are known as ___________.

self-contained

400

The tendency of different components of blends to leak at different rates

 Fractionation

400

_________ are controlled by the Montreal Protocol.

Chlorofluorocarbons, Hydrochlorofluorocarbons, and Halons

400

According to EPA; on low pressure chillers, moisture most frequently enters the system through air leaks in areas where there are

gaskets or fittings

500

________ recovery devices are so named because they depend on components of the system. That is, they capture refrigerant with the assistance of components in the air conditioning or refrigeration equipment they are emptying.

System-dependent

500

______________releases associated with good faith attempts to recapture and recycle or safely dispose of refrigerant substances shall not be subjected to the prohibition set forth in the Clean Air Act

De-minimis

500

In regard to refrigerants, B-3 indicates

toxic, high Flammability

500

ASHRAE is an anachronym for 

American Society of Heating, Refrigerating and Air-Conditioning Engineers

500

Major repair is defined by EPA as a repair involving removal of the appliance compressor, condenser, evaporator, or

auxiliary heat exchanger coil