AT THE CORE OF IT ALL
5 LBS OR LESS
UNDER HIGH PRESSURE
LESS THAN 30 PSI
RANDOMS AND DATES
100

WHAT IS THE STATE OF REFRIGERANT BETWEEN THE EVAPORATOR AND THE COMPRESSOR?

LOW PRESSURE VAPOR 

100

WHAT IS THE AMOUNT OF REFERANT CHARGE THAT NEEDS TO BE RECOVERED FROM A OPERATING COMPRESSOR?

IN-OPERATING COMPRESSOR?

2 PART QUESTION 

OPERATING COMPRESSOR = 90% 

IN-OPERATING COMPRESSOR = 80 %

100

WHAT IS THE DIFFERENCE BETWEEN ACTIVE RECOVERY AND PASSIVE RECOVERY?

ACTIVE = USING RECOVERY MACHINE

PASSIVE = USING SYSTEM COMPRESSOR

100

DAILY DOUBLE!!!!!!!!!!!

WHAT IS THE PURPOSE OF A PURGE UNIT ON A CHILLER?

REMOVE NON-CONDENSABLES 

100

WHAT YEAR WAS THE MONTREAL PROTOCAL SIGNED 

1987

200

A SINGLE CHLORINE ATOM CAN LAST HOW LONG IN THE STRATOSPHERE?

120 YEARS / 100,000 ATOMS 

200

WHAT MAKES A TYPE 1 SYSTEM A TYPE 1 SYSTEM?

5 LBS OR LESS OF REFRIGERANT

HERMAICLY SEALED SYSTEM 

NO ACESS VALVES 

200

WHAT IS THE REFRIGERANT LEAK RATE FOR COMMERCIAL REFRIGERATION?

20 %

200

LOW PRESSURE SYSTEMS (TYPE 3) EQUIPMENT WORKS UNDER WHAT PSIG?

30 PSIG 

200

WHAT RATING OR STANDARD IS ASSOICATED WITH RECLAIMED REFRIGERANT 

AHRI 700

300

HOW OFTEN DOES A PRESSURIZED CYLINDER NEEDS TO BE HYDROSTATICLY TETSED?

EVERY 5 YEARS

300

WHAT DOES S.N.A.P. STAND FOR?

SIGNIFICANT NEW ALTERNATIVES POLICY 

300

DAILY DOUBLE!!!!!!!!!!!!!!!!

WHAT IS THE DIFFERENCE BETWEEN ZEOTROPIC AND NON-AZEOTROPIC REFRIGERANT. 

DIFFERENT BOILING POINTS 

300

WHAT IS THE BLUE SIDE OF THE GAUGE ON THE REFRIGERANT MANIFOLD CALLED?

COMPOUND GAUGE

300

DAILY DOUBLE !!!!!!!!!!

WHAT YEAR WAS IT MANDATED TO BE CERTIFIED WITH TAKING THE EPA TEST?


1994

400

DAILY DOUBLE !!!!!!!!!

WHAT IS IT CALLED WHEN A MINOR AMOUNT OF REFRIGERANT IS RELEASED FROM YOUR HOSES?

DE-MINIMIS

400

WHAT SHOULD BE USED TO HELP RELEASE TRAPPED REFRIGERANT FROM OIL FROM A SYSTEM?

HEAT GUN 

RUBBER MALLET 

400

DURING A SYSTEM RECOVERY AND OR REPAIR, A PUNGENT ODOR IS DECTECTED, WHAT DOES THAT NORMALLY INDICATE?

COMPRESSOR BURNOUT

400

WHAT IS THE LEAK RATE REQUIRMENT FOR INDUSTRIAL PROCESS REFRIGERATION?   

30 %

400

DAILY DOUBLE !!!!!!!!!!!!!

PROPANE CYLINDERS FOR GRILLING SHOULD NEVER BE USED AS A REFRIGERANT.........WHY? 

THEY INCLUDE IMPURITIES 
500

WHAT IS THE BASELINE REGRIGERANT FOR GWP?                             ( BASE OF 1)

R-744 = CO2

500

WHAT SHOULD BE USED TO REMOVE ICE FROM A SIGHT GLASS?

ISOPROPYL ALCOHOL

500

IF AFTER INSTALLING A PEIRCING VALVE AND YOU FIND THE SYSTEM PRESSURE AT 0 PSIG, WHAT TYPE OF RECOVERY SHOULD YOU PERFORM?

NONE, THERE IS NO REFRIGERNANT IN THE SYSTEM. 

500

WHAT IS THE PSIG THAT A RUPTURE DISK FAILS AT?

10 PSIG 

500

WHAT YEAR WAS THE PHASE OUT OF R-22 REFRIGERANT?

2020

M