EPA TYPE 1
EPA TYPE 2
UNWRITTEN RULES
EPA TYPE 1,2,3
EPA TYPE 2 (MORE)
100

To work on small appliances after November 14th 1993

What is TYPE 1?

100

This must be done before charging a system with refrigerant 

What is pressurized with Nitrogen and pressure test?

100

Never do this going to a call back after your company was there and saw the last technician did a terrible job 

What is telling the customer that

100

This specific class of refrigerant will not be manufactured after 1995 

What are CFCs?

100

This tool is used to find a general area to pinpoint a leak 

What is an electronic/ ultrasonic leak detector?

200

The maximum amount of refrigerant in a small appliance 

What is 5 pounds or less?

200

Traces of oil residue sighting on copper fittings indicates that this is happening 

What is a leak 

200

You do this seeing a technician with a single hose and a bucket full of water going to the roof

What is RUN!

200

This will start to leak out overtime and should never be left in an appliance. 

What is a piercing valve?

200

These are the ways to visually see if you have a leak (3 answer)  

What are soap bubbles, trace of oil, excess of superheat?

300

Before disposing of small appliance containing R-12, you have to do this 

What is recover the refrigerant? 

300

Split air systems equipment that contains 5 pounds or more 

What is type 2 universal?

300
Being new in the field under 3 years you are this person 

What is a yes person?

300

industrial and commercial equipment over 50 pounds with a leak rate of this percentage needs to be repaired under EPA regulations. 

What is 35%?

300

In. of HG (inhg) stands for the measurement of this element  

What are inches of mercury?

400

This can manually or automatically close when disconnecting hoses to prevent refrigerant loss   

What are low loss fittings?

400

The most common refrigerant for 30 years that was before the outlawing CFCs and HCFCs 

What is R 22?

400

Being in a crawl space or attic you are able to do this but never in front of the customer 

What is be on your phone 

400

Where most of the liquid refrigerant that is recovered from the system will be found here. 

What is the receiver (when applied)

400

The number of microns needed to completely evacuate the system

What is 500 microns?

500

System manufactured, charged and hermetically sealed with 5 pounds or less of refrigerant 

What is the best definition of Type 1 "small appliances" as defined by the EPA? 

500

The removal of the compressor, condenser, evaporator coil, or heat exchanger are considered 

What is "major" repair considered by the epa

500

NEVER EVER EVER SAY THIS IN FRONT OF A CUSTOMER (CONSIDERED THE M WORD)

What is MOLD?

500

The owner must have records of all refrigerants added to the unit that contains these many pounds or more of charge. 

What is 50 pounds?

500

This is where the receiver is and the state of the refrigerant leaving the receiver 

What is after the condenser and leaves as a high pressure/temperature liquid? 