Autoclave
BMBT
Oxygen Cage
AeroKat
Other Equipment
100

What TEMPERATURE and TIME is required to autoclave surgical packs? How long is the dry cycle?

Temp: 273 F
Time: 45 minutes
Dry cycle: 30 minutes

100

Where is the Buccal Mucosal Bleeding Time (BMBT) test located?

In the cart behind the Tx table, 4th drawer on the left side

100

What liquid is used in the 2 bottles/bubblers?

Distilled water

100

Where is our AreoKat located?

With the crash box - not inside the crash box

100

How should the red bag for the BedJet be positioned?

With the blue words towards the patient

200

What is the TEMPERATURE and TIME required to autoclave dental packs? How long is the dry cycle?

Temp: 250 F
Time: 30 minutes
Dry cycle: 30 minutes

200

What position(s) can the patient be in for the test?

Sternal or lateral

200

What does the “Shor-Line” device measure?

Temperature and humidity in the cage

200

Where is the Flovent/Puffer located

Inside the crash box

200

What brand of syringe must be used for the syringe pump?

BD

300

If you have 2 different sized wrapping materials, in what order would you use them for a single pack?

Larger wrap on inside (touching instruments/drape)
Smaller material on outside

300

What anesthetic agents cannot be used for the test?

Narcotics

300

What does the Handi+ measure?

Oxygen % in the cage

300

List 2 tips to tell clients when introducing the AreoKat to their cat

- Practice putting chamber to cat's face without medication - smear treat on inside of mask or place mask on face then reward with treat and slowly increase time with mask on face.
- depress flovent before putting mask to cat's face (cover mask end while depressing flovent)

300

Demonstrate how to email radiographs to a client/referral clinic.

1) Open ULite on favourites/bookmark bar and sign in
2) Right click on desired study and click "Share"
3) Enter client name and email, then click "Add"
4) Write in comment box if desired and click "Send"

400

How are instruments in a sterilization bag positioned in the autoclave?

Plastic side down or on its side in the wire rack.

400

What supplies are needed to perform a BMBT test?

Bleeding time device
Stopwatch/timer
Gauze roll
Filter paper or gauze squares

400

What strategy can be used if the patient is getting too warm inside the oxygen cage?

Add ice packs to the square container, around the blue bubbler, on the oxygen cage door.

400

How many breaths should the patient take before removing the AreoKat from their face?

7-10 breaths - watch/count the "Flow-Vu" (flutter valve)

400

Demonstrate how to set up the VetCorder and connect to the iPad

1) Plug in monitoring lines into the red VetCorder unit.
2) Turn on Unit and select "Monitor Vitals"
3) Connect lines to patient
4) Open "MonitorVitals" on iPad and select "Vetcorder 0324" 

500

List all the steps to use the autoclave - be specific.

1) Place packs in autoclave and turn on
2) Turn dial to "Fill Water" and allow water to flow in the chamber until reaches the fill line
3) Turn dial to "Sterilize"
4) Close autoclave door and spin handle to seal. Careful not to overtighten - 2-finger tighten
5) Set temp dial to desired heat
6) Set time dial to desired time
7) After sterilization cycle is complete, turn dial to "EXH/DRY", allow white needle to drop to "0", then crack open the door
8) Set timer for 30 minutes for the dry cycle

500

List the steps to perform BMBT

1) Position patient in lateral or sternal recumbency.

2) Wrap gauze strip securely around maxilla with lip folded up, exposing mucosal surface. (Do not occlude blood flow)
3) Remove square-shaped safety guard from the top of the device but do not depress yet
4) Place device flush against mucosal surface that is free of obvious surface vessels - apply light pressure.
5) Press tab to release the scalpel blade
6) Let incision bleed freely and begin timing. Blot excess blood as needed with filter paper or gauze being careful not to disturb incision site or clot.
7) Stop timer when paper/gauze no longer soaks up blood

 
500

Where are our extra supplies for the oxygen cage located?

In the cart behind the Tx table, bottom drawer on the right.

500

List all the steps for using the AeroKat - be specific

1) Remove cap and shake the inhaler
2) Insert inhaler into AeroKat Chamber
3) Gently apply mask to cat's face and depress the inhaler. Or cover mask with your hand and depress inhaler then gently apply mask to the cat's face.
4) Hold mask in place for 7-10 breaths
5) Remove mask and gently wipe the cat's face with a damp cloth to remove residual medication from their fur.

500

Demonstrate how to add times to radiographs - i.e. if doing a barium series.

1) With desired rad on screen, click the settings gear icon
2) Select the pencil icon
3) Select "custom" and type desired time and click "enter"
4) Move time to desired location on rad and click the pencil icon and click "done" to complete