FIRE HOSE
VALVES & APPLIANCES
FIRE HYDRANTS
FIRE ATTACK
HOSE CARE & STORING
100

Fire Hose that transport water from a fire hydrant or other water supply source to an apparatus equipped with a pump.

What is supply hose. 

100

Type of valve applied to hydrants to control the flow.

What is Gate Valve

100

The hydrants in the PNW are these type of hydrants.

What is Dry-Barrel Hydrants

100

This nozzle has a straight, smooth tip, and produces a solid stream of water.

What is smooth bore nozzle

100

This hose roll allows the firefighter to control both of the couplings

What is donut roll.

200

The traditional length of fire hose sections in North America.

What is 50 ft. 

200

Appliance to divide a single hoseline into two or more lines.

What is Wye appliances

200

Fire hydrants must be opened and closed slowly to prevent this.

What is water hammer

200

Before advancing a hose line into a structure, a firefighter should always open the nozzle fully to check this.

What is adequate water flow OR pressure

200

On a female coupling, two things should always be checked before connecting. Name one of them.

What is gasket or swivel

300

The name of the wrench used to tighten fire hose connections/couplings

What is the spanner wrench. 

300

Appliance to combine multiple lines into one line.

What is Siamese appliance

300

This must be done when shutting down a dry-barrel hydrant. 

What is verify that all of the water drains out 

300

This stream can be used for hydraulic ventilation.

What is Fog stream

300

This hose load can be carried on the shoulder, completely clear of the ground, which makes it less likely that the hose will catch on obstacles.

What is Minuteman load

400

Most common coupling on large diameter hose

What is Storz

400

What type of valve is used in a Siamese appliance to allow water to only flow in one direction?

What is Clapper valve

400

The large outlet on a hydrant is referred to as

What is steamer connection OR pumper outlet nozzle.

400

When the fire is to large for  handlines, or hose streams are needed in areas unsafe for firefighters, you would use this device.

What is Master Stream device

400

How often should fire hose be service tested.

What is Annually. (once a year)

500

The name of the indicator on a male and female coupling to prevent cross-threading.

What is Higbee cut

500

A fitting that would be used to connect two male couplings of the same diameter.

What is double-female

500

The hydrant wrench is attached to this to open and close the hydrant.

What is stem nut

500

In addition to a dump site at the fire and a fill site at the water source, this is needed for a water shuttle operation.

What is a mobile water supply apparatus to haul the water. (Tender)

500

This type of damage can occur to natural fiber hose when it is stored wet, putting it at risk of mold and mildew.

What is Organic damage 

M
e
n
u