100

Which of the following protects the motor against dangerous overheating due to overload and failure to start.

  •  Thermal Protector
  •  Both Thermal Protector and Short Circuit Protector
  •  Surge Protector
  •  Thermal Protector
100

Overhead service conductors shall be installed beneath openings through which materials may be moved, such as openings in farm and commercial buildings

  •  False
  •  True

False

 NEC Code 230.9(C)

100

The front edge of the cabinets situated in walls constructed of noncombustible materials such as concrete and tile must be within ____ of the finished surface: 

  •  6 mm
  •  10 mm
  •  8 mm
  •  4 mm

6 mm

NEC Code 312.3

100

Lighting track or pendent shall not be located within a zone measured ____ vertically from the top of a bathtub rim:

  •  8 ft
  •  6 ft
  •  7 ft
  •  9 ft

8 ft

NEC Code 410.10(D)

100

Receptacles are not permitted less than ____ from the inside walls of a storable pool

  •  6 ft
  •  8 ft
  •  5 ft
  •  4 ft

6 ft

NEC Code 680.22(A)(1)


200

The greatest root-mean-square (rms) difference of potential between any two conductors of the circuit:

  •  Voltage
  •  Ampere
  •  Power Factor
  •  Power

Voltage

200

Service conductors installed in conduit under _____ of earth beneath the building are also considered outside the building

  •  12 inches
  •  18 inches
  •  20 inches
  •  24 inches

18 inches

NEC Code 230.6(4)

200

The radius of curvature of inner edge of any bend must be at least ____ times the diameter of the service entrance cable: 

  •  5
  •  10
  •  7.5
  •  2.5

5

NEC Code – 338.24


200

Recessed or surface-mounted luminaires and recessed exhaust fans may be located within 8 ft from vertically from the top of a bathtub rim:

  •  True
  •  False

True

NEC Code 410.10(D)

200

The fire alarm circuit disconnect shall be permitted to be secured in the __ position.

  •  OFF
  •  ON
  •  Either ON or OFF

ON

 NEC Code 760.41(A)

300

The circuit conductors between the final overcurrent device protecting the circuit and the outlet(s)

  •  Branch Circuits
  •  Service Lateral
  •  Feeder Circuit

Branch Circuits

300

Conductors run above the top level of a window shall have a vertical clearance not less than the  3 feet:

  •  False
  •  True

False

NEC Code 230.9(A) Exp

300

In damp and wet location, a minimum of ____ air space between the enclosure and the wall or other supporting surface is required: 

  •  6 mm
  •  5 mm
  •  8 mm
  •  10 mm

6 mm

NEC Code 312.2

300

Lamp tie wires, mounting screws, and decorative bands on glass spaced atleast _____from lamp terminals shall not be required to be grounded:

  •  2.5 inches
  •  2 inches
  •  1 inch
  •  1.5 inches

1.5 inches

NEC Code 410.42

300

The branch circuit supplying the fire alarm equipment(s) shall supply no other loads.

  •  True
  •  False

 True

NEC Code 760.41(B)

400

The common point on a wye-connection in a polyphase system or midpoint on a single-phase system

  •  Neutral
  •  Ground
  •  Jumper

Neutral

400

The connections that depend on solder shall not be used for connecting the terminals of service conductors:

  •  False
  •  True

True

 NEC Code 230.81

400

Galvanized steel and stainless steel RMC can be used under all atmospheric conditions, within all types of occupancies:

  •  True
  •  False

True

NEC Code 344.10(A)(1)

400

Lampholders near Combustible Materials shall be constructed, installed or equipped with shades or guards such that the combustible material is not subjected to exceed the temperature of about ____

  •  90
  •  75
  •  100
  •  100

90

NEC Code 410.97

400

All metal raceways and all non-current-carrying metal parts of fixed and portable electrical equipment, regardless of voltage, installed in a motor fuel dispensing facility shall be grounded and bonded. 

True 

False

True

NEC 514.16

500

Rendered inaccessible by the structure or finish of the building.

Concealed

500

Where it is impracticable to locate the service head or gooseneck above the point of attachment, the service head or gooseneck location shall be permitted not farther than _____ from the point of attachment.

24 inches

NEC Code 230.54(C) Exp

500

The minimum approved electrical trade size for RMC is _____:


0.5 inches

NEC Code 344.20(A)

500

In case of the conductors supplying several motor and other loads, the conductors ampacity shall not be less than ____ of the continuous non motor load:


125%

NEC Code 430.24 (4)

500

In a nonventilated commercial garage, classified as a "minor repair garage," a receptacle outlet is being installed two feet from an unventilated pit. In this installation, the area above the floor up to a level of ? is a Class I, Division

18"

511.3(c)

M