Weeks 01+02+03
Weeks 04+05
Weeks 06+07+08
Weeks 09+10
Weeks 11+12+13
100

This organization is a private, nonprofit organization that oversees the creation of voluntary standards for a variety of manufacturing processes, products, systems, services, and personnel.

What is ANSI? (American National Standards Institute)

100

There are ten (10) occupancy groups. What are they? (Whoever names the most wins this question)

Assembly: Group A-1, A-2, A-3, A-4, A-5 

Business: Group B 

Educational: Group E 

Factory + Industrial: Group F-1, F-2 

High Hazard: Group H-1, H-2, H-3, H-4, H-5 

Institutional: Group I-1, I-2, I-3, I-4 

Mercantile: Group M 

Residential: Group R-1, R-2, R-3, R-4 

Storage: Group S-1, S-2 

Utility + Misc: Group U

100

What is the conditions required for the MAXIMUM Exit Access Travel Distance permitted by code? And what is that distance?

Occupancy: F-2, S-2, U

Automatic Sprinkler System

400' Travel Distance

Table 1017.2

100

When installing sprinklers in a Historic R-1 Building with transoms above each hallway door, what are you required to do?

Transoms must be closed in fixed position, and sprinklers must be installed on both sides of the transom.

1203.4

100

Difference between Candela, Lumen and Lux

Candela - Strength of light emission.

Lumen - Amount of light that is radiated.

Lux - Illumination intensity of an area.

200

Term used to describe "a discriminatory practice in which services (financial and otherwise) are withheld from potential customers who reside in neighborhoods classified as "hazardous" to investment."

What is Redlining

200

The minimum amount of distance between buildings to allow for 0 hours of exterior wall fire rating.

30 feet

200

When a space has fixed seating WITHOUT dividing arms (For example, church pews) how is the number of seats calculated?

One person for each 18" of seating length. 

1004.6 - Fixed Seating

200

Beams, Girders and Ducts are required to be what minimum height above finished floor in basements?

6'-4"

R305.1.1

200

When are separate plumbing facilities not required in a Mercantile building?

When occupant load is 100 or less.

300

What are the three components of Light Pollution?

Sky Glow = brightening of the night sky over inhabited areas.

Light Trespass = light that shines where it is not needed or wanted.

Glare = excessive brightness that causes visual discomfort.

300

Which type of plastic is not permitted on furnishing in Group A Occupancies?

Pyroxylin Plastic

806.6

Imitation Leather, or really old movie film reels. (Many movies filmed before the 30s no longer exist as many just simply exploded.) 

300

Define the difference between a Dwelling Unit and Sleeping Unit.

Dwelling Unit – “A single unit providing complete, independent living facility for one or more persons, including permanent provisions for living, sleeping, eating, cooking and sanitation.” 

Sleeping Unit – “A single unit that provides rooms or spaces for one of more person, includes permanent provisions for sleeping and can include provisions for living, eating and either sanitation of kitchen facilities but not both.

300

Which type of exterior opening is NOT required to open directly into a public way?

Skylights

1204.2.2 - Exterior Openings (Exceptions)

300

A property claim made by the contractor against the owner when they are not paid for the completed work.

Lien

400

What was the first building to make New Yorkers realize that they needed to create a comprehensive zoning ordinance?

Equitable Building

400

What is the Minimum Fire Window Assembly Rating (Hours) required in Party Walls?

Not Permitted

Table 716.1(3)

Party Walls are walls that are built DIRECTLY onto a property line. (Think of buildings touching each other in an urban setting.)

400

When designing an accessible Means of Egress, no door or door opening mechanism can require more than ___ Pounds Per Square Foot to open or operate.

5 Pounds Per Square Foot

400

Habitable rooms must have glazing that is at least _% of the room’s floor area OR artificial lighting that has an average illumination of _ footcandles.

8%

10 Footcandles

400

Show you understand the difference between an Affirmative and Negative Covenant. 

A development covenant is an agreement sometimes used in conjunction with real estate transactions to impose obligations on the purchase, which vary by agreement.

A covenant that requires the homeowner to keep the trees trimmed in the yard is an affirmative covenant.

A negative covenant prohibits a person to act. For example, a negative covenant can forbid a homeowner to build fences.

500

Vodka, Champagne, Whiskey and Bud Light...While no good students consumes any of these, what Occupancy Classification would production facilities of these be classified as?

Vodka: F-1

Champagne: F-2

Whiskey: F-1

Bud Light: F-2

500

What test standards MUST an Acoustic Ceiling adhere to per the code?

ASTM C635

ASTM C636

500

What is the size required for (1) Area of Refuge space? How many are required per how many occupants?

30" x 48"

1 space per 200 occupants

500

This method, often used for Historic Buildings, allows "for the existing buildings to be evaluated so as to show that alterations, while not meeting new construction requirements, will improve the current existing situation"

Performance Compliance Method

500

OUR LAST JEOPARDY QUESTION

Building Codes will not be many of your favorite subject. However, was there any areas you wanted to learn more about, or wish we discussed in class or in a lecture?

I have to review all your answers. 


This helps adjust the course to cover student interests as well. In fact, the last week's lecture on going through a real world project and code review came from many students asking for it. 

M
e
n
u