Accessibility
Occupant Load
Fire Ratings
Egress
Occupancy Types & Building Restrictions
100

What is our state's accessibility code called?

TAS, Texas Accessibility Standards

100

When measuring a building to determine the occupant load, this type of area includes all miscellaneous spaces

Gross

100

Automatic sprinkler systems have no effect on the allowable area of building (T/F)

False

100

What is the max. dead-end corridor length typically allowed by the codes in a non-sprinklered building?

20 feet

100

The various types of conditions that can occur in a building that will help determine the occupancy classification are called what?

Risk Factors

200

What is the max required dimension to the top rim of a urinal?

17"

200

In order to determine the occupant load for a space, you must know what two things?

Load factor and square footage

200

If more than one type of construction exists within a single building, each type of construction must be separated from the other by a fire wall

True

200

What is the formula for determining exit locations in a non-sprinklered building

1/2 of the diagonal dimension

200

A skating rink would fall under which occupancy?

Assembly A-4

300

What is the required dimension for the centerline of a toilet to the wall?

17"-18"

300

What is the occupant load for a multi-purpose room with tables and chairs measuring 140' x 90'?

840 OL

300

Which construction type is the most restrictive?

I

300

If an entire building is equipped with an automatic sprinkler system, most codes will allow the minimum distance between exits to be reduced to:

1/3 of the diagonal distance

300

An animal hospital would fall under which occupancy type?

Business

400

What are the min. clear dimensions needed on both the push side and the pull side of a door, front approach?

Pull side: 18"

Push side: 12"

400

What is the occupant load of a shoe store measuring 80' x 60'?

80 OL

400

In a Type III-B building, the exterior bearing walls are required to what what rating?

2 Hours

400

What is the width variable for doors? Both non-sprinklered and sprinklered

NS: 0.2

S: 0.15

400

What are the building restrictions for a building classified as Assembly with Type II-B construction, not sprinklered?

55' high

2 stories above grade

9,500 sf 

500

In a bathroom, which clearance must exist at a sink?

30" x 48"

500

Find the total occupant load, round up:

30' bench

15' booth

15' booth

25' bench

30' bench

73 OL

500

Which construction type is solely heavy timber?

IV
500

A single flight of stairs can not rise more than ____ before needing a landing

12'

500

Allowable building area and height are based on:

Construction type

M
e
n