It's Electric
Get Bent
Name That Code
Don't be a Tool
That's Alarming!
200

This is the basic unit of resistance

What is an OHM

200

This term describes a bend in a conduit intended to bring the pipe up from a lower level, and accuracy in its height measurement is crucial for correct installation.

What is STUB UP

200

National Fire Alarm & Signaling Code

what is NFPA 72

200

This device can be used to measure Voltage, Resistance and Current.

What is a MULTIMETER

200

This type of smoke detector operates on the light-scattering principle

What is a PHOTOELECTRIC DETECTOR

400

Also known as Elctro Motive Force, in electrical equations, the symbol for this is E

what is Voltage

400

In conduit bending, this term refers to the amount of conduit length that is subtracted from your actual stub height when creating a 90-degree elbow.

What is TAKE UP

400

National Electrical Code

What is NFPA 70

400

This device can be used to analyze AC waveforms.

What is an OSCILLISCOPE

400

This is nominal spacing for spot-type smoke detectors

What is 30 FEET

600

The fourth color band on a resistor indicates this.

What is tolerance

600

This type of bend is used to navigate a conduit around obstacles; common angles to achieve this include 30 and 45 degrees.

What is OFFSET

600

Life Safety Code

What is NFPA 101

600

This device is used to measure FM, AM, and single-sideband signals in an application such as a mobile communications system or a BDA / ERCES system.

what is an RF FIELD STRENGTH ANALYZER

600

The operable part of a manually actuated alarm-initiating device shall be not less than ______ or more than ______ from the finished floor.

What is 42 INCHES & 48 INCHES

800

This type of material has properties that fall between those of a conductor and an insulator.

What is a semi-conductor

800

In the context of bending angles in conduits, these values are used to calculate the necessary length of conduit between various bends, ensuring accuracy and efficiency. 

What are MULTIPLIERS

800

Standard on Clean Agent Fire Extinguishing Systems

What is NFPA 2001

800

This device can be used to inject signals into a circuit to help in troubleshooting

What is a WAVEFORM GENERATOR

800

The is the standard alarm evacuation signal

What is the 3 Pulse Temporal Pattern

1000

The effective value of AC voltage is known by this three letter designation and is 0.707 times the peak value

What is RMS

1000

This term describes two consecutive 90 degree bends in a single conduit that are made to route the pipe in parallel lines.

What is a BACK to BACK bend

1000

Standard for Fire Safety & Emergency Signals

What is NFPA 170

1000

This device can be used to measure speech intelligibility in a voice evacuation system.

What is a STI or (STIPA) Analyzer

1000

This is the color marking for a HIGH temperature heat detector (250F - 324F)

What is BLUE