Forcible Entry & Overhaul, Conservation, Scene Preservation
Structural Search + Rescue
Tactical Ventilation
All About Hoes
Fire Suppression
100

Which tools are used to open walls and floors during overhaul?

axes


100

Limitation of using a thermal imager for a structural search 

What is May not be able to detect fires on a lower floor if structure is carpeted? 

100

The action immediately following ventilating a compartment that is in ventilation-limited decay 

What is Water application to cool gases and surfaces? 

100

What is the water delivery device that flows a minimum of 350 gallons of water per minute called?

Master stream

100

Once firefighters have verified from the outside that the floor above the basement is there, this is the only reliable way to determine if the floor is structurally sound 

What is Visually inspecting the floor joists? 

200

The structural integrity of a building is most affected by the intensity of the fire and

the amount of water used for extinguishment

200

The priority before any search

What is Locating and isolating the fire? 

200

The goal of tactical ventilation performed as part of overhaul 

What is To reduce smoke damage to structure? 

200

Automatic fog nozzles maintain a near constant _______ regardless of the pattern setting 

Pressure 

200

The primary mission at most incidents involving small unattached structures such as storage sheds, pump houses, or fishing houses 

What is Prevent fire spread to exposures and then extinguish the fire? 

300

Spalled concrete is an indicator of

possible loss of structural integrity

300

The oriented-search method used in primary search. 

What is The team leader remains anchored while others search the room; the crew remains in constant communication

300

Never direct a ______ stream into a horizontal exhaust opening when interior attack crews are inside the structure because it will force smoke, heat, and steam toward them

What is a Fog stream? 

300

The hydrant discharge outlets considered standard 

At least one large outlet (4 or 4.5'') and two hose outlets for 2.5'' couplings 

300

Th three main influences on ground cover fire behavior 

What is Fuel, weather, and topography? 

400

Where is the hinge on a casement window

On one side

400

Before an incident, a gas monitor is typically calibrated using: 

What is A known quantity of a manufacturer approved calibration gas?

400

The stack effect is 

fire, smoke, and hot gases move upward through a highrise creating an upward draft 

400

Generally speaking, how many gallons per minute does a 2 1/2" fire hose line flow?

250 gpm 

400

To extinguish a fire by reducting its temperature, enough water must be applied to stop the gas chemical reaction and: 

What is Absorb the heat being generated? 

500

How many people are needed to use a battering ram?

2-4

500

The purpose of a primary search 

What is To rapidly determine the location of victims? 

500

When using positive-pressure ventilation to ventilate a multistory building, it is best to 

apply positive pressure at the lowest point (ground level) 

500

What is the indicator notch on hose couplings that lines up when the threads are lined up to engage properly?

The Higbee indicator

500

At the entry point of a structure fire with an upper layer of smoke and hot gases, these actions will help improve interior conditions

What is Applying the water to the ceiling using a straight stream in a side-to-side motion? 