What am I?
Vocab Terms
Let's Relay
ICS and other things
NFPA
100

I respond to chemical spills, control leaks, and perform decontamination. What is my title?

What is a Hazardous Materials Technician?

100

I am objectives that are required to be completed during the operational phase of an incident. What am I called?

What are tactical benchmarks?

100

What appliance allows an additional pumper to hook up into an existing relay operation without shutting down the entire relay operation?

What is a Relay valve?

100

The ideal span of control is ideally between ______ and 7. 

What is 5?

100

NFPA standards are generally based on ______________.

What is consensus?

200
In the early days of firefighting, I was used to pull down a burning building and prevent fire from spreading to nearby structures. What am I?

What is a fire hook?

200

What term refers to the water pressure on the discharge manifold of the fire pump at the point of gauge attachment?

What is discharge pressure?

200

A relay pumper is needed if the discharge pressure exceeds _______ for large-diameter hose.

What is 80 psi?

200

The goal of  __________________ is to ensure that all members of a department perform a given task in the same manner. 

What are standard operating procedure?

200

Which NFPA standard contains information on testing of an apparatus breathing air systems?

What is NFPA 1989?

300

I am a type of fire apparatus designed to carry large quantities of water to a fire scene. What am I called?

What is a mobile water supply?

300

The distance that a fire apparatus travels from the time that the brakes are activated until the apparatus makes a complete stop is know as the __________ distance.

What is braking?

300

During a relay operation, what piece of equipment can a driver/operator use to split a single large-diameter hoseline into two or three medium-sized hoselines?

What is a Manifold?

300

Organizing an incident by breaking down the overall strategy into a series of smaller tasks is an example of what?

What is the division of labor?

300
According to NFPA 1901, a pumper should be equipped with a permanently mounted pump at a minimum rating of ___________ of water per minute.

What is 750 gallons

400

I have specialized knowledge and training for high-angle rescue, structural collapse, trench rescue, confined-space, and similar operations. What is my title?

What is a Technical Rescuer?

400

What does the ABCDE acronym stand for in commercial driving?

What is abrasions, bulging, cuts, dry-rot, even-wear
400

A relay pumper is needed if the discharge pressure exceeds ________ for medium diameter hose.

What is 175 psi?

400

The ____________ is a collection of permanent rules published by the federal government, and includes 50 titles that represent broad areas of interest that are governed by federal regulation.

What is the Code of Federal Regulations?

400

According to NFPA 1901, what is the minimum amount of attack hose to be carried on a pumper?

What is 400ft?

500

Specialized apparatus/equipment has been developed for particular situations. These types of fire apparatus are distinguished based on their _____________ and ___________ at the emergency scene.

What are the functions and capabilities?

500

What term refers to when the brake drums become hot and expand away from the brake shoes, causing the brakes to heat up until they become less effective?

What is brake fade?

500

What is the purpose of a relay pumper in a relay operation?

What is increase water pressure provided to the next pumper in the operation?
500

One result of the first National Firefighter Life Safety Summit in 2004 was the creation of the:

What is the Everyone Goes Home Program?

500

Which chapter of NFPA standard 1002 lists the "general requirements" all members who operate fire department vehicles must meet?

What is chapter 4?

M
e
n
u