GRILL IT UP SAFETY
FIRE EXTINGUISHERS
SMOKE ALARM SAFETY
EGRESS
FIRE ALARMS
100
Name a type of BBQ grill.
What is propane or charcoal?
100
Portable fire extinguishers are covered in the IFC section_____
What is 906
100
Smoke alarms should be tested this often using the test button.
What is once a month?
100
Doors from common apartment buildings directly into swimming pool areas can only be reversed if the occupancy of the room the door is on is less than?
What is 50
100
This section if the IFC covers fire alarms
What is 907
200
BBQ grills should only be used ____.
What is outdoors.
200
The NFPA referenced standard for fire extinguishers is____
What is NFPA 10
200
True or False. Smoke alarms should be inside every bedroom, outside each sleeping area, and on every level of the home, including the basement.
What is True?
200
_________ is a continuous and unobstructed path of vertical and horizontal egress or exit travel from any occupied point in a building or structure to a public way.
What is a "Means of Egress"
200
The referenced NFPA standard for fire alarms is
What is NFPA 72
300
This should never be left unattended, placed away from the home, and out from under eaves and overhanging branches.
What is a grill?
300
Typically, the minimum rating on fire extinguishers in most occupancies is:
What is 2A10BC
300
For the best protection, do this to smoke alarms so when one sounds they all sound.
What is interconnect?
300
The three elements of means of egress
What are Exit access, exit, and exit discharge
300
If a fire alarm system is impaired you can order the evacuation of the building or ____ _____ per IFC 901.7
What is fire watch
400
Keep your grill clean by removing this type of build up from cooking surface and trays below the grill.
What is grease or fat?
400
Generally speaking, fire extinguishers may be spaced every ____ in most occupancies
What is 75 feet
400
This kind of smoke alarm is more responsive to flaming fires.
What is ionization.
400
Doors serving as a component of a means of egress must be ____ wide at a minimum
What is 36 inches
400
Persons wanting to conduct fire drills using the fire alarm system in their occupancy are required to call their_____ ____ and provide notice
What is their alarm company
500
When using gas grills check this for leaks before using it for the first time each year.
What is a hose?
500
Fire extinguishers must be hung on a wall or placed on a shelf and be no lower than __ and no higher than ___
What is 3 feet and 5 feet
500
Ionization or Photoelectric. For smoldering fires, this type of smoke alarm is more responsive.
What is Photoelectric?
500
Emergency lighting must provide the proper amount of illumination for a period of no less than
What is 90 minutes
500
Test records must be kept on site for review by the fire inspector. Those records must include: Test date Detector types Location Type of test AND.............
What is "RESULTS OF THE TEST"