Fire Dynamics
Ropes & Knots
Ladders
PPE
Anything Fire
100

Off gassing of a solid is a physical change known as

Pryolysis

100

This type of rope is used to hoist tools, equipment, or establish a perimeter

Utility rope

100

This type of ladder has sections that travel in guides or brackets to permit length adjustment

Extension Ladder

100

Structural Firefighting gear is made of how many layers of material

Three

100

An 1-3/4" attack hose line should be capable of flowing ___ gpm

160 gpm

200

Process in which water turns into a gas (steam)

Vaporization

200

Rope made of this material that is not properly cleaned and stored can mold and/or mildew

Natural Fiber

200

According to NFPA, ground ladders should be inspected after each use and 

Monthly 
200

This type of SCBA exhaust exhaled air out into the atmosphere 

Open-Circuit

200

Smoke is a product of incomplete combustion, smoke is also referred to as

FUEL

300

These 4 elements (____, _____, _____, _____,) need to be present to sustain fire and is known as the _________

Oxygen, Heat, Fuel, Chemical Chain reaction

Fire Tetrahedron

300

This type of Knot is used when typing Webbing

Water Knot

300

A ladder should be extended how far above a roof line to ensure footing and handhold when stepping on and off of the roof

3 to 5 rungs above

300

If a firefighter is motionless for ____ seconds ____ device will sound

30 seconds

Personal alert safety system (PASS)

300

#1 priority of a Firefighter 

LIFE SAFETY

400

Minimum temperature at which a liquid produces sufficient vapors to ignite but will not sustain combustion. 

Flash Point

400

This type of knot is used as a Safety knot

Overhand Knot

400

This type of ladder is used during roof operations and is equipped with foldable hooks

Roof Ladder

400

When checking the air-cylinder gauge prior to donning an SCBA, the gauge should read no less than

No less than 90% of cylinder capacity

400

This type of control valve on a sprinkler system has a site window with the words "open" and "shut" and is located remotely away from the building 

Post Indicator Valve (PIV)

500

The invisible line formed in a bi-directional flow path that separated the inlet and the outlet of a ventilation opening 

Neutral Plane

500

Most common type of life safety rope is construction in this manner

Kernmantle

500
When using a ground ladder for rescue the tip of the ladder should be placed where?
At the bottom of the windowsill 
500

If a firefighter is low on air and needs additional air to exit a IDLH atmosphere this connection can be made between two SCBA's

Buddy Breather

500

List the 4 stages of a fire

Incipient, Growth, Fully Developed, Decay